7. GENERAL INFORMATION
7.1 DIAGNOSIS
7.1.1 PROTECTION CIRCUIT CONTROL SPECIFICATION
TEMPIN
Temperature
(
°
C)
Fan
Remarks
More than 191
175 to 190
156 to 174
134 to 155
Less than 133
More than 100
90 to 100
80 to 90
70 to 80
Less than 70
ON
ON
ON
Leading hold
OFF
Mute ON & speaker relay OFF :
The warning indication "OVERHEAT"
Leading hold
Mute OFF & speaker relay ON :
Normal mode
Microcomputer-related ports
FAN_DRIVE (Expansion IC) : For Fan on/off
TEMP_IN (pin 94)
Input port (A/D) : To detect temperature
FAN_STOP (pin 95)
Input port : To detect Fan forced stop
OL_DET (pin 73)
Input port : To detect overloading at the amplifier
(Interrupt port)
DC_DET (pin 63)
Input port : For DC detection
12V_DET (pin 2)
Input port : To detect 12V trigger
The following control processes are activated immediately before
the relay system is turned on upon power-on. The time is 4.8
seconds after power-on. (Control of the relay system is enabled
5.2 seconds after power-on.)
Only DC detection is enabled 2 seconds after power-on to activate
it before other protection functions.
1
Fan control
1) Fan control
2) Fan detection
If the fan is forcibly stopped, the FAN_DET port becomes "L".
Detecting "L" the microcomputer performs the following
operations:
1. System muting on
2. Protection relays off
The warning indication "FAN STOP" appears (flashing) on the
FL display.
If this status continues for more than 3 seconds, the power is
turned off (for Standby mode).
If the port becomes "H" within 3 seconds, the unit resets
automatically.
FAN_DET port performs the chattering check for 1 msec.
In addition, there is the case that detection delays for maximum
20 msec because performs monitor of FAN_DET port with a main
loop.
3) Thermistor open detection
If a total (total of 50 times) of A/D value (TEMPIN) for one
second is less than 250, the indication "THDCT NG" flashes.
If this status continues for 3 seconds, the power becomes the
standby mode.
2
Overload detection
(abnormality detection)
If the speaker terminals are short-circuited or low-load driving is
detected, the OL_DET port becomes "L".
Detecting "L" edge interrupt in an interrupt process, the
microcomputer performs the following operations:
1. System muting on
2. Speaker relay off (Control with the display microcomputer)
3. Power off (Standby mode)
3
DC detection (defect detection)
Only DC detection is enabled 2 seconds after power-on.
If there is a fault in the power amplifier or a high-level signal
lower than 5 Hz is input, the DC_DET port becomes "L".
Detecting "L" the microcomputer performs the following
operations:
1. System muting on
2. Speaker relay off (Control with the display microcomputer)
The warning indication "AMP ERR" appears on the FL display.
If this status continues for more than 3 seconds, the power is
turned off (for Standby mode) and flashes the standby LED.
Do not accept the key input afterward.
(Flash it always till turns the primary side off.)
If the port becomes "L" within 3 seconds, the unit resets
automatically.
DC_DET port performs the chattering check for 1 msec.
In addition, there is the case that detection delays for maximum
20 msec because performs monitor of DC_DET port with a main
loop.
Even if turns the primary side off and turns on once again,
standby LED flashes as it is.
If detects DC once and turned the power off, do not accept the key
input afterward.
However, power on is possible when the following key was
pressed to be able to key input in the protection line and service.
1. Test mode (remote control code : A55F)
2. When the STEREO/DIRECT key and STREAM DIRECT key
are both held pressed for 2 seconds.
(It is effective only when turned the power off with DC
detection regarding step 2.)