10. Install the core unit in the PRV-LX1.
The core unit is a component only for the
PRA-BD12 output board. To install the
PRA-BD11 input board, go to Step 11.
Thread the FFC cable (L) through the opening
in the core. Install the core unit to the rear
bridge using supplied nylon rivet as shown in
the figure on the right. Then secure the core
using the screw (with washer).
Notes:
Press in the nylon rivet until the rivet head is
flush with the surface.
Watch out for sharp edges (on arms and the
rear bridge, for example) when installing the core
unit.
Note:
To prevent load being exerted on the FFC cable
(L) when installing the core unit, place the
core beside the arm recess, then hold the
core unit at an angle (
angle, as shown in the
figure) to route the FFC cable as close to the
f
connector as possible.
Screw,
with washer
Nylon rivet
Core opening
Core unit
Rear bridge
Contact surface
(See Step 4)
FFC cable (L)
PRA-BD12 output board
Unlock connector
f
.
Route the FFC cable (L) through the opening in the
core, insert the cable in connector
f
and lock by
lowering the stopper . See figure and note below (*).
Arm recess
Core
FFC cable (L)
PRA-BD12 output board
Core unit
FFC cable (L)
Press in the nylon
rivet until the rivet
head is flush with
the surface.
Note:
Watch out for sharp edges (for example, the arms and the rear bridge)
when connecting and routing the FFC cable (L).
Blue reinforced side
(two lines)
Unlocked
Locked
*
Make sure that the two lines in the reinforcement
are not visible when the connector is locked. If
they are still visible, disconnect and connect the
FFC cable again.
•
•
•