6.2 DRIVE ASSY ADJUSTMENT
How to readjust the timing of the control signals when the DRIVE Assy TND506MD is
to be replaced
As there is a large difference in delay time among the individual TND506MDs, timing adjustment has been made on each
TND506MD in the unit process. If the TND506MD is replaced on the X or Y Drive Assy, readjustment of the timing of the
control signals is required.
• How to adjust
Adjust the timing between the startup of the control signals of SUS-U1, SUS-D1, SUS-U2, and SUS-D2 and the startup
of the voltage between the gate and the source of the output FET, with the VR resistors that are inserted in the signal
line in series. When adjusting, set the unit to Drive OFF mode, and Vsus to 0 V. (For details on how to set to Drive OFF
mode, see "7.1.5 Power on/off function for the large-signal system".)
• Specified values for adjustment and adjustment points
Note:
Connect GND of the probe with DGND (DGND: X Drive Assy: K1020, Y Drive Assy: K2010) for input signal.
For outputting a signal, obtain a signal from the FET gate terminal.
For adjustment, magnify any pulse in the waveform.
VGS=5V line
Magnify.
500us/div
50ns/div
Input signal: 1V/div
Output FET VGS 5V/div
Assy
Replaced IC
Signal for which Readjustment is Required
X DRIVE
IC1101
XSUS-U2 & XSUS-D2
IC1102
XSUS-U1 & XSUS-D1
Y DRIVE
IC2201
YSUS-U1 & YSUS-D1
IC2202
YSUS-U2 & YSUS-D2
X DRIVE
Y DRIVE
Signal Name
Set Value for
Delay Time
Input
Signal
Output
Signal
Adjustment
VR
Input
Signal
Output
Signal
Adjustment
VR
SUS-U1
375ns
±
10ns
K1005
Q1108
VR1103
K2025
Q2202
VR2201
SUS-D1
375ns
±
10ns
K1009
Q1112
VR1104
K2027
Q2205
VR2202
SUS-U2
375ns
±
10ns
K1008
Q1103
VR1101
K2022
Q2208
VR2203
SUS-D2
375ns
±
10ns
K1006
Q1105
VR1102
K2024
Q2212
VR2204
Waveform of the
control signal
(input signal)
VGS waveform
(output signal)
• Actually measured waveforms
Adjust so that the delay is
in the range of 375
±
10 ns.
About 2.5V