] QAL (Shutdown information for the display main unit)
Command
Format
Effective status
Function
Remarks
[QAL]
Every time
To acquire up to the 8 latest shutdown
logs managed by the Panel Main
microcomputer
Up to the 8 latest shutdown logs of the display main unit can be acquired.
Return data: 3 (ECO) + 96 (DATA) + 2 (CS) = 101 Byte
ECO
Echo back
3
"QAL"
1
Data on the latest shutdown
12
Reasons of the latest 8 shutdowns and hour-meter
data when the shutdowns were generated
(For details, see the tables below.)
2
Data on the 2nd latest shutdown
12
3
Data on the 3rd latest shutdown
12
4
Data on the 4th latest shutdown
12
5
Data on the 5th latest shutdown
12
6
Data on the 6th latest shutdown
12
7
Data on the 7th latest shutdown
12
8
Data on the 8th latest shutdown
12
CS
Check sum
2
(CS)
Order
Content
Length
(BYTE)
Value
Remarks
1
SD category data
1
SD category (For details, see the table below.)
0 for no SD
2
SD subcategory data
1
SD subcategory (For details, see the table below.)
3
HOUR METER
7
Time when a shutdown managed by the Panel Main
microcomputer was generated
All digits are padded with asterisks when there was no SD.
4
Dummy
3
All digits are padded with asterisks.
SD category
(response)
Reason for SD
w/wo
subcategory
SD subcategory
(response)
Reason for subcategory
"0"
N
o SD (no abnormality)
W
ithout subcategory
"0"
"5"
Shutdown signal from D-Amp.
Short-circuit of speaker terminal.
W
ith subcategory
"1"
"2"
"6"
Failure in module microcomputer communication
W
ithout subcategory
"0"
"8"
Failure in IIC communication
W
ith subcategory
"1"
Displayport receiver
A_
N
G_B : L
OT
W
: L
"2"
Failure in AUDIO P
W
M IC communication
"A"
FA
N
stop
W
ith subcategory
"1"
FA
N
_A stop
"2"
FA
N
_B stop
"B"
Abnormal temperature of the display
unit (high)
W
ith subcategory
"1"
High temperature at Temperature Sensor 1
"2"
High temperature at Temperature Sensor 2
"D"
Abnormality in power of the Display MAI
N
Assy
W
ith subcategory
"1"
Abnormality in 6.5
V
power supply.
Data Arrangement
Data
Length
Output
Example
Remarks
Shutdown (SD) data
SD categories/SD subcategories
Содержание KURO KRP-500P
Страница 11: ...11 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F 2 3 PANEL FACILITIES WYSIXK5 and WYS5 types only LFT and WA5 types ...
Страница 12: ...12 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit for WYSIXK5 and WYS5 types ...
Страница 13: ...13 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F Remote Control Unit for LFT type ...
Страница 14: ...14 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit for WA5 type ...
Страница 19: ...19 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 20: ...20 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Страница 22: ...22 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 4 2 OVERALL WIRING DIAGRAM 2 2 ...
Страница 23: ...23 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F OVERALL DIAGRAM KRP 500P ...
Страница 139: ...139 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 148: ...148 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 9 5 REAR SECTION POWER SUPPLY P8 Refer to 9 6 FRONT SECTION ...
Страница 156: ...156 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 9 9 PANEL CHASSIS SECTION ...