79
KRP-500P
5
6
7
8
5
6
7
8
A
B
C
D
E
F
[2] QS2 (PANEL OPERATION DATA)
Data Arrangement
Data
Length
Output Example
ECO
3 byte
QS2
1
N
otify of the standby operation transition
1 byte
1
2
Adjustment flag of the main unit
1 byte
0
3
Adjustment-data backup flag
1 byte
0
4
"1st PD" data
1 byte
0
5
"2nd PD" data
1 byte
0
0
6
Color sensor data
1 byte
∗∗
∗∗∗∗
∗∗∗
7
Reserved
2 byte
8
Temperature data (TEMP 1)
3 byte
128
9
SD data
1 byte
0
10
SD subcategory data
1 byte
0
11
Operation status induced by SD
1 byte
0
12
Reserved
3 byte
00000259
13
HOUR METER
8 byte
0
0
0
0
14
MASK indication
1 byte
0
4A
15
Still picture detection
1 byte
16
SCA
N
protection detection
1 byte
17
Panel crack detection
1 byte
18
19
Address emergency detection
1 byte
Reserved
4 byte
CS
2 Byte
2 byte
1: Power supply status
0
Shifting to Passive
Standby is not
possible.
P
During power O
N
1
Shifting to Passive
Standby is possible.
2: Adjustment flag of
the main unit
0
Adjustment completed
1
Adjustment not
completed
3: Adjustment-data
backup
flag
0
Adjustment completed
1
Adjustment not completed
4, 5: PD data
0
N
o PD data
2
PO
W
ER
3
SCA
N
4
SC
N
-5
V
6
Y-DCDC
7
Y-SUS
8
ADRS
A
X-DCDC
10-1: SD subcategory (SQ_LSI)
0
N
o SD-Sub data
1
Communication error
2
Drive stop
3
BUSY
4
V
ersion mismatching (H/S)
B
X-SUS
C
DIG-DCDC
F
U
N
K
N
O
WN
9: SD data
0
N
o SD
1
SQ_LSI
2
MDU-DE
V
ICE
3
RST2
4
Panel temperature
11: Operation status
induced by SD
0
N
ormal
1
Relay-off completed
2
During warning
indication
14: MASK indication
0
MASK-OFF
1
MASK-O
N
15 to 1
8
: Detection of Each Protection function
0
N
ormal operation
1
At detection of protection operation
Command
Format
Effective Operation
Modes
Function
Remarks
[QS2]
Every Time
Output of status
Return data: 3 (ECO) + 34 (DATA) + 2 (CS) = 39 Byte
The command QS2 is for acquiring data on the panel's operational information.
10-2: SD subcategory (MDU-DEVICE)
0
N
o SD-Sub data
1
EEPROM
2
BACKUP
3
DAC
6: Color sensor data
-
Function OFF (including standby)
0
N
ormal
1
Hardware connection is not completed
2
Data mismatching
10-3: SD subcategory
(Panel temperature)
0
N
o SD-Sub data
1
Panel high temperature
2
Panel low temperature
5
V
ersion mismatching (H/M)
6
V
ersion mismatching (H/I)
Содержание KURO KRP-500P
Страница 11: ...11 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F 2 3 PANEL FACILITIES WYSIXK5 and WYS5 types only LFT and WA5 types ...
Страница 12: ...12 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit for WYSIXK5 and WYS5 types ...
Страница 13: ...13 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F Remote Control Unit for LFT type ...
Страница 14: ...14 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit for WA5 type ...
Страница 19: ...19 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 20: ...20 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Страница 22: ...22 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 4 2 OVERALL WIRING DIAGRAM 2 2 ...
Страница 23: ...23 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F OVERALL DIAGRAM KRP 500P ...
Страница 139: ...139 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 148: ...148 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 9 5 REAR SECTION POWER SUPPLY P8 Refer to 9 6 FRONT SECTION ...
Страница 156: ...156 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 9 9 PANEL CHASSIS SECTION ...