NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

Operation

Starting the Heater: (Ignition)

1. Fill the tank with kerosene or other approved fuel 

until needle on fuel gauge points to “F”.

2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong  

(grounded) power source. You must use a 

three prong (grounded) extension cord that is at 

least 6 feet long and is a minimum of 14 AWG 

rating. 

Model 45-KFA:

1. Complete steps 1-3 above.
2. Move power switch to “On” position. The power 

indicator light will illuminate and the heater will 

ignite.

 Stopping / Restarting Heater:

 - To stop the heater, move the power switch to the “Off” 

position and unplug the power cord.

 - To restart the heater; wait 10 seconds and follow 

ignition steps.

Models 75T-KFA - 215T-KFA:

1. Complete “starting heater ignition” steps 1-3 

above

2. Turn thermostat control knob to desired 

temperature setting. The thermostat set range 

is from 40 ºF to 110 ºF.

3. Move power switch to “On” position. The power 

indicator light and room temperature display will 

illuminate and heater will ignite. 

NOTE: 45-75T-KFA models do not have a room    

 

temperature display feature.

The room temperature display will indicate the 

following:

  

- When the temperature is less than 0 ºF the 

   display says “LO”.

 - When the temperature is more that 99 ºF the 

   display says “HI”.

 - Between 0 

°

F and 99 

°

F the display shows

   actual temperature.

 

Stopping / Restarting Heater:

 - To stop the heater, move the power switch to the “Off” 

position and unplug the power cord.

 - To restart the heater; wait 10 seconds and follow 

ignition steps.

Long Term Storage:

Models 45-KFA - 75T-KFA:

1.  Use an approved siphon to drain fuel through the 

fuel cap opening. 

Models 135T-KFA - 215T-KFA:

1.  Drain fuel through the drain plug in the bottom 

of the fuel tank.

2.  To remove the drain plug, pull the plug grip 

downward and remove the seal head from the 

drain hole in the tank. 

3.  Using a small amount of kerosene, rinse and 

swirl the kerosene inside of the fuel tank, empty 

the tank fully. 

4.  To replace the drain plug; push the drain head 

fully into the drain hole and secure by pushing 

the seal cap fully into the head hole.  

IMPORTANT: Never store leftover kerosene between 

seasons, using old fuel can damage heater.

6

TIP: If the heater does not ignite; move 

switch to “Off” position, check steps 1-3 

above and then move switch to “On” position.

TIP: If the heater does not ignite, the 

thermostat may be set too low. Turn the 

control knob to a higher setting until the 

heater ignites. If the heater does not ignite; move 

switch to “Off” position, check steps 1-3 above 

and then move switch to “On” position.

Содержание REMINGTON REM-135T-KFA-O

Страница 1: ...to Ventilation on Page 5 FACTORY ID 001 Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heate...

Страница 2: ...use for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98...

Страница 3: ...ls away from this heater Minimum Clearance From Combustibles 45 190T KFA 215T KFA Top 4 ft 4 ft Sides 4 ft 4 ft Front 8 ft 10 ft ALWAYS locate heater on a stable and level surface If your heater is eq...

Страница 4: ...Manual 3 Wiring Diagrams 45 KFA 75T 215T KFA Assembly Instructions What s In The Box Models 45 KFA 75T KFA Remove the heater and all packaging materials from the shipping carton Note Save the box and...

Страница 5: ...lace heater on wheel support and line up holes on the fuel tank lip 5 Attach front handle with 2 long screws 50 mm and 2 nuts through the second hole from the front on both sides of the tank lip and w...

Страница 6: ...R use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should only be stored in a blue contain...

Страница 7: ...temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F the display says HI Between 0 F and 99 F the display s...

Страница 8: ...starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fuel...

Страница 9: ...ESSURE While heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 75T KFA...

Страница 10: ...proper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh kerose...

Страница 11: ...POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 10 14 11 13 8 12 9 30 26 3 16 2 4 6 1 7 22 24 17 18 19 21 30 20 15 41 33 35 36 29 28 5 32 31 25 27 38 37 3...

Страница 12: ...21 0510 70 021 0520 70 021 0520 18 Pump Body 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 19 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 20 End Pump Cover 70 0...

Страница 13: ...If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Страница 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Страница 15: ...n de seguridad PELIGRO DE INCENDIO QUEMADURAS INHALACI N Y EXPLOSI N Mantenga los combustibles como materiales de construcci n papel o cart n a una distancia prudente del calentador seg n lo recomien...

Страница 16: ...efacci n temporal de edificios en construcci n modificaci n o reparaci n Fuego directo significa que todos los productos de combusti n del calentador ingresan en el espacio calentado Este aparato tien...

Страница 17: ...a todos los materiales combustibles lejos de este calentador Separaci n m nima entre el calentador y materiales combustibles 45 190T KFA 215T KFA Superior 4 pies 1 2 m 4 pies 1 2 m Lados 4 pies 1 2 m...

Страница 18: ...NTROL DE TEMP FOTOC LULA SENSOR DE AMBIENTE NEGRO NEGRO NEGRO NEGRO NEGRO NEGRO NEGRO NEGRO NEGRO TIERRA TIERRA VERDE VERDE BLANCO BLANCO BLANCO ROJO AZUL NEGRO NOTA Los modelos 125T 135T 175T 190T 21...

Страница 19: ...orte de las ruedas y alinee los orificios en el reborde del tanque de combustible 5 Fije el asa delantera con 2 tornillos largos 50 mm y 2 tuercas a trav s del segundo orificio desde el frente en ambo...

Страница 20: ...enado de una temporada a la siguiente El queroseno se deteriora con el tiempo EL QUEROSENO VIEJO NO SE QUEMAR ADECUADAMENTE EN ESTE CALENTADOR NOTA El queroseno debe almacenarse nicamente en un conten...

Страница 21: ...talla mostrar LO Cuando la temperatura es superior a 99 F 37 2 C la pantalla mostrar HI Entre 0 F 18 C y 99 F 37 2 C el indicador mostrar la temperatura actual Apagado Reencendido del calentador Para...

Страница 22: ...FILTRO DE COMBUSTIBLE El filtro de combustible debe limpiarse al menos dos veces por cada temporada de calefacci n Enjuague el filtro con queroseno K 1 limpio El combustible contaminado podr a hacer q...

Страница 23: ...A Mientras el calentador est funcionando gire la v lvula de seguridad hacia la derecha para aumentar la presi n o hacia la izquierda para disminuirla A continuaci n se muestra la presi n correcta de l...

Страница 24: ...resi n de la bomba 3 Limpie o reemplace la buj a 4 Limpie o reemplace el filtro de combustible 5 Limpie o reemplace la boquilla 6 Enjuague el interior del tanque con queroseno nuevo y limpio 7 Inspecc...

Страница 25: ...E DE ALIMENTACI N 2017 Pinnacle Climate Technologies Inc Manual del usuario del calentador de aire forzado de queroseno 10 14 11 13 8 12 9 30 26 3 16 2 4 6 1 7 22 24 17 18 19 21 30 20 15 41 33 35 36 2...

Страница 26: ...21 0500 70 021 0500 70 021 0510 70 021 0520 70 021 0520 18 Cuerpo de la bomba 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 19 Juego de rotor 70 022 0100 70 022 0100 70 022 0100 70 022 0...

Страница 27: ...le Climate Technologies Inc descubre que el art culo est en condiciones normales de funcionamiento o que no est defectuoso se devolver el art culo con el flete por cobrar Esta Garant a Limitada reempl...

Страница 28: ...dustrial Blvd 101 Sauk Rapids MN 56379 EE UU Llamada sin costo 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Correo electr nico info pinnacleclimate com 2017 Pinnacle Climate Technologies...

Отзывы: