16
7.
Press ENTER and then scroll DOWN to adjust date and time accordingly. Pressing ENTER at the EXIT screen will
revert to Service Menu.
8.
Scroll UP until Program 1 / End Program Mode is reached. At this point press ENTER and the display will return to the
MANUAL INHIBIT screen.
9.
To restart the system, press and hold the scroll UP key for 5 seconds.
10.
System will now resume its previous automatic status.
11.
When the SYSTEM HEALTHY screen is visible, scroll DOWN to observe engineer display 1:
The normal DC Volts reading should be in the range of:
Hyprolyser Compact 240 = 12v (+/-1v) 100A
Hyprolyser Compact 480 = 24v (+/-1v) 100A
*
The DC volts reading may take several hours to stabilize on initial commissioning owing to the water/brine solution
strength stabilising.
12.
Using a DC clamp ammeter, check that the DC current is at 100A (+/- 5A during the initial running-in period).
13.
Continue to scroll DOWN to observe Eng. Display 4 which provides a visual indication of the hydrogen threshold as a
percentage. An acceptable level of <50% should always be the case. The hydrogen gas detect system is factory set
and requires only an annual service inspection/test.
14.
After 12 to 24 hours of operation it is recommended to perform a chlorine product strength test. The result should
ideally read 0.6% +/- 0.1%.
15.
Complete a Commissioning record.
System commissioning completed.