background image

                                                                                                                                                

 

-1- 

DGS 

Installation Instructions 
Инструкция по установке

 

Instrucciones de Instalación

 

הנקתה תוארוה

 

English,

 

Русский, Español, 

תירבע

 

 

 

 

 

1  220VAC Adapter 
2  Yellow LED 
3  Red LED 
4  Green LED 
5  Test/Silence Button 
6  Ventilation Slots 
7  Mounting Bracket 
8  Battery Compartment (Back Side, 

Bracket Removed) 

 

1  Блок питания 220В AC 

1  Adaptador 220VAC 

 חכ קפס

220V AC

 

1

 

2  Желтый светодиод 

2  LED Amarillo 

הבוהצ תירונ

 

2

 

3  Красный светодиод 

3  LED Rojo 

המודא תירונ

 

3

 

4  Зеленый светодиод 

4  LED Verde 

הקורי תירונ

 

4

 

5  Кнопка Тест/Прерывание звукового 

сигнала 

5  Botón para Prueba/Silencio 

הקתשה/הקידב רותפכ

 

5

 

6  Вентиляционные отверстия 

6  Ranuras de ventilación 

רורווא יצירח

 

6

 

7  Кронштейн 

7  Soporte de montaje 

יאלגה הלתמ

 

7

 

8  Батарейный отсек (расположен сзади, 

доступен при снятом кронштейне)  

8  Compartimento de la batería (en la parte 

posterior de la unidad sin el soporte de montaje) 

 ,ירוחא דצ( תוללוס את

)הלתמה אלל

 

8

 

 

DGS Wireless Gas Detector 

The DGS is a FastLink technology wireless indoor gas detector, designed for the 

FORCE series 

and 

VISION

 intruder alarm systems. Using 

the DGS in 

FORCE

 requires the installation of a wireless receiver. 

The fully supervised DGS detector can detect the presence of Liquefied Petroleum Gas (LPG), and wirelessly alerts the control panel.  
LPG includes propane gas (C3H8), mainly used as fuel in heating appliances, cooking equipment, and vehicles.  
The detector monitors the presence of gas once every 10 seconds and performs a self-test every 160 seconds. Once the concentration 

of the gas reaches the detection threshold, it triggers an alarm, by sounding beeps every one second, along with the red LED flashing. 
The DGS is powered by a 220V AC transformer, which connects with a micro USB cable (included). The detector’s battery is only used 

for monitoring and alerting on AC power loss.  
The DGS alerts on low battery condition, and has a tamper switch that alerts when its enclosure is opened or removed from the wall.  
For enrollment information, see the alarm system’s Installation guide. 

 

Cautions: 

 

 

The DGS’s backup battery only purpose is to monitor if AC power is loss. The detector does 
not detect or alert on gas leak without AC power!  

 

The DGS is based on wireless (RF) transmissions. Any wireless transmission can be subject 
to RF interference and, although unlikely, this interference may cause the DGS to not operate 
as intended. RF transmissions will be attenuated by tinted glass, in wall isolation with metal 
foils, metal objects, etc. 

2 3 4

7

6

8

5

1

Содержание 8832004

Страница 1: ...ances cooking equipment and vehicles The detector monitors the presence of gas once every 10 seconds and performs a self test every 160 seconds Once the concentration of the gas reaches the detection...

Страница 2: ...ked into place 5 Test the detector see how below How to install the DGS Mount the detector on a flat surface Follow the next steps 1 Remove the detector from the mounting bracket no 7 in the figure ab...

Страница 3: ...mode Low battery condition is detected when the battery voltage drops below 2 6V After that the battery can last for up to one month Maintenance and Troubleshooting The DGS must be tested once every...

Страница 4: ...etector s battery is only used for monitoring and alerting on AC power loss DGS AC AC 433 92 DGS143 DGS243 868 95 DGS187 DGS287 5 5 UL 1484 EN 50194 25 EN 50131 1 CE 11 9 8 4 4 o 100 240 AC 5 DC USB o...

Страница 5: ...5 4 5 220 AC 6 DGS 3 Description 3 3 10 160 9 1 5 4 4 DGS 3 CR123A AC 5 20 1 5 2 6 1 AC 2 48 3 48 1 48 48 4 0 5 48 5 DGS143 P N 8832004 DGS187 P N 8832009 DGS243 P N 8832204 DGS287 P N 8832209...

Страница 6: ...GS287 Sensibilidad Cumple con UL 1484 y EN 50194 antes del 25 del LEL Duraci n estimada de la bater a Hasta 5 a os en uso t pico Dimensiones 11 9 X 8 X 4 4 cm Normativas Cumple con las normas EN 50131...

Страница 7: ...mal Modo de espera el modo de funcionamiento normal durante el cual se muestrea el aire circundante cada 10 segundos y el detector se prueba a s mismo cada 160 segundos El LED verde se mantendr ilumin...

Страница 8: ...gundos Todas las funciones de detecci n y alarma se suspenden hasta que se restaure la alimentaci n Condici n de problema El LED parpadea tres veces y se escucha un pitido una vez cada 48 segundos Fin...

Страница 9: ...9 DGS 1 2 8 3 4 5 DGS 1 7 2 DGS 3 4 5 DGS 3 5 5 DGS 5 DGS CR123A 3V 20 2 6V 30...

Страница 10: ...10 DGS DGS 48 48 48 48 48 DGS143 8832004 DGS243 8832204...

Страница 11: ...o que no haya sufrido o sufra alguna forma de manejo malintencionado as como tampoco garantiza que el Producto vaya o pueda prevenir cualquier muerte y o da os corporales y o da os a la propiedad o cu...

Страница 12: ...12 P N 4410476 4410476 Revision C1 XX multi Nov 2020...

Отзывы: