Technical details order no. 6D000012-6D000013
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
| 86
13
Technical details order no. 6D000012-6D000013
General
6D000012
6D000013
Certifications
CE, TÜV, cULus Listed
CE, TÜV, cULus Listed
ESPE type
3
3
Product type
Light
Light
Sensor's mode of operation
Optical
Optical
Resolutions
40 mm, 70 mm
40 mm, 70 mm
Number of zone sets that can be
switched
10
10
Operating range
Warning zone at 70 mm resolu-
tion
0,05 - 40 m
0,05 - 40 m
Warning zone at 40 mm resolu-
tion
0,05 - 22 m
0,05 - 22 m
Safety zone at 70 mm resolution
0,05 - 3 m
0,05 - 5,5 m
Safety zone at 40 mm resolution
0,05 - 3 m
0,05 - 3 m
Number of simultaneously mon-
itored safety zones
1
1
Number of simultaneously mon-
itored zones
2
2
Number of zone configurations
10
10
Electrical data
6D000012
6D000013
Supply voltage
Voltage
24 V
24 V
Kind
DC
DC
Voltage tolerance
-20 %/+25 %
-20 %/+25 %
Output of external power supply
(DC)
8 W
8 W
Max. output power
27 W
27 W
Residual ripple DC
5 %
5 %
Max. inductive load per output
2 H
2 H
Protection class
3
3
Optical data
6D000012
6D000013
Diameter light spot on front plate
8 mm
8 mm
Used wavelength range
905 nm
905 nm
Laser class (DIN EN 60825-1)
1
1
Scan area
275°
275°
Max. opening angle scanner
0,12°
0,12°
Angle resolution
0,1°
0,1°
Max. number multiple evaluation
16
16
Detectable remission area
1,8 - 1.000 %
1,8 - 1.000 %
Pulse duration
3 ns
3 ns
Typical output power laser
8 mW
8 mW
Measuring circuit
6D000012
6D000013
Input resistance
12 kOhm
12 kOhm