Operation
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
| 74
Message in the display
Status
Description/measure
Icon
Text
OVERRIDE
Override is active.
OVR
TIMEOUT
Override has elapsed.
10.2
Display of the monitoring status
Icon
Status
Description/measure
Valid config-
uration
Configura-
tion not yet
accepted
Device is switched on and ready for
operation
Warning zone has been violated
A violation of the warning zone has
been detected. The configured ac-
tion for a violation of the warning
zone has been triggered.
Safety zone has been violated
A violation of the safety zone has
been detected. The OSSDs are in
the OFF state.
Change detected in the reference
outline
A violation of the reference outline
has been detected. The area of
change is highlighted in blue.
Check the cause for the change and
eliminate the cause or adapt the ref-
erence outline.