Wiring
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
| 47
}
M12 12-pin male connector for connection to an evaluation device and the supply voltage
– An OSSD pair
– One configurable input
– Four configurable inputs/outputs
– Two inputs for supply voltage
– Functional earth
Pin/colour
Description
1
Brown
24 V DC
4
Green
24 V DC
2
Blue
0 V DC
6
Yellow
0 V DC
3
White
7
Black
9
Red
10
Purple
11
Grey/pink
8
Grey
OSSD 1
5
Pink
OSSD 2
12
Red/blue
Functional earth
}
M12 8-pin socket, hinged
– not used
}
M12 4-pin socket, hinged
Connection of the safety laser scanner to the configuration PC
The configurable inputs can be used for all input signals.
}
Restart and reset
}
EDM (when using the 12-pin connection)
}
Switching the monitoring of zone sets
}
Dynamic and static muting
The configurable inputs and outputs can be used for both input signals and output signals.
6.2.1
Configurable inputs
When using the 8-pin connection, the configurable inputs at PIN 3 and 4 can be used for
the following functions:
}
Restart
}
Reset
}
Restart or reset
}
Zone set switching
}
Muting 1 and 2
}
Dynamic activation of the muting state