PSEN op2.1 L/ 2.2 TMuting Set
Operating Manual PSEN op2.1 L/ 2.2 TMuting Set
1003535EN01
10
24V DC
[1]
[2]
[3]
[4]
Muting 1
Muting 2
Fig.: Wiring of 4 muting sensors on the receiver's 5pin connector
24V DC
[1]
[4]
Muting 2
Muting 1
Fig.: Wiring of 2 muting sensors on the receiver's 5pin connector
Legend
[1] Wiring of muting sensor A1 on Pin 2 (Muting 1) of connector
[2] Wiring of muting sensor A2 on Pin 2 (Muting 1) of connector
[3] Wiring of muting sensor B1 on Pin 4 (Muting 2) of connector
[4] Wiring of muting sensor B2 on Pin 4 (Muting 2) of connector
Earthing of muting sensors
Attach the earth connection in the drill hole provided on the side of the muting sensors us
ing the screw provided. The drill holes for the earthing screw are on the right and left side of
the muting sensors, at the same height.
Identify the earthing contact using the adhesive label provided.