PSEN op2.1 L/ 2.2 TMuting Set
Operating Manual PSEN op2.1 L/ 2.2 TMuting Set
1003535EN01
16
Environmental data
630820
630821
Vibration
In accordance with the standard
EN 6006826
EN 6006826
Frequency
10,0 55,0 Hz
10,0 55,0 Hz
Amplitude
0,35 mm
0,35 mm
Shock stress
In accordance with the standard
EN 60068229
EN 60068229
Acceleration
10g
10g
Duration
16 ms
16 ms
Airgap creepage
Pollution degree
2
2
Protection type
In accordance with the standard
EN 60529
EN 60529
Housing
IP65
IP65
Mechanical data
630820
630821
Material
Top
Aluminium
Aluminium
Dimensions
Height
60,0 mm
60,0 mm
Width
355,3 mm
655,1 mm
Depth
40,0 mm
40,0 mm
Weight
1.100 g
1.800 g
PSEN op2.3 LReflex and PSEN op2.4 LReflector
General
630822
630823
Approvals
CE
CE
Sensor's mode of operation
optical
–
Electrical data
630822
630823
Supply voltage
Voltage
24,0 V
24,0 V
Kind
DC
DC
Voltage tolerance
20 %/+20 %
20 %/+20 %
Protection class
1
1
Optical data
630822
630823
Operating range
0,5 3,0 m
–
Used wavelength range
650 nm
–
Environmental data
630822
630823
Ambient temperature
Temperature range
10 55 °C
10 55 °C
Storage temperature
Temperature range
25 70 °C
25 70 °C
Climatic suitability
Humidity
95 % r. h. at 55 °C
95 % r. h. at 55 °C
Condensation during operation
Not permitted
Not permitted