PSEN op2.1 L/ 2.2 TMuting Set
Operating Manual PSEN op2.1 L/ 2.2 TMuting Set
1003535EN01
11
Commissioning
Orientation
1. Check that the safety light grid is aligned correctly and that the safety light grid is in nor
mal operation. The green LED on the receiver, the yellow LED on the transmitter and
both yellow LEDs on the receiver must be lit.
2. Make sure the DIP switches are set correctly for the choice of muting configuration.
–
If you are using the PSEN op2.1 LMuting Set, set DIP switches 2 and 6 to OFF.
–
If you are using the PSEN op2.1 TMuting Set, set DIP switches 2 and 6 to ON.
3. Use the LED to check the alignment of the muting sensors.
4. Modify the position of the muting sensors on the safety light grid until the red LEDs on
the sensors go out (see diagram).
–
Vertical alignment of the muting sensors: Undo the hexagonal screws and move the
mounting profile upwards.
–
Horizontal alignment of the muting sensors: Loosen the hexagonal screws and
move the mounting profile within the slot hole for the hexagonal screws.
[1]
[2]
Legend:
[1]: Move the muting sensor upwards on the mounting profile for vertical alignment
[2]: Move the muting sensor within the slot hole for horizontal alignment