34
Lateral and vertical offset
Lateral offset
Vertical offset
[1]
[2]
[3]
[4]
[4]
[5]
[6]
Power / Fault
Safety Gate
Input
[4]
[4]
Legend:
}
[1]: Hysteresis
}
[2]: Typical operating distance S
O
}
[3]: Typical release distance S
r
}
[4]: Offset in mm
}
[5]: Operating distance in mm
}
[6]: Response range
Wiring
Please note:
}
Information given in the
Technical details [
43]
must be followed.
}
The max. cable length l
max
in the input circuit is calculated from
– the max. cable capacitance at the safety outputs (see
Technical data [
43]
).
– the minimum permitted supply voltage at the sensor (19.2 V).
}
The power supply must meet the regulations for extra low voltages with protective sep-
aration (SELV, PELV).
}
The inputs and outputs of the safety switch must have a protective separation to
voltages over 60 VDC.
PSEN cs1.13p ATEX
Operating Manual PSEN cs1.13p ATEX