44
Semiconductor outputs
Short circuit-proof
Yes
Residual current at outputs
10 µA
Voltage drop at OSSDs
3,5 V
Lowest operating current
0 mA
Utilisation category in accordance with EN 60947-1
DC-12
Times
Test pulse duration, safety outputs
450 µs
Switch-on delay
after UB is applied
1 s
Inputs typ.
13 ms
Inputs max.
20 ms
Actuator typ.
45 ms
Actuator max.
100 ms
Delay-on de-energisation
Inputs typ.
15 ms
Inputs max.
20 ms
Actuator typ.
30 ms
Actuator max.
260 ms
Risk time in accordance with EN 60947-5-3
260 ms
Supply interruption before de-energisation
20 ms
Simultaneity, channel 1 and 2
∞
Environmental data
ATEX approval
SEV 12 ATEX 0122 X
ATEX category, gas
II 3G Ex mc nAc IIC T6
ATEX category, dust
II 3D Ex mc tc IIIC T80°C IP67
Application area
X: -25°C ≤ ta ≤ +50°C
Ambient temperature
In accordance with the standard
EN 60068-2-14
Temperature range
-25 - 50 °C
Storage temperature
In accordance with the standard
EN 60068-2-1/-2
Climatic suitability
In accordance with the standard
EN 60068-2-78
Humidity
93 % r. h. at 40 °C
EMC
EN 60947-5-3
Vibration
In accordance with the standard
EN 60947-5-2
Frequency
10 - 55 Hz
Amplitude
1 mm
Shock stress
In accordance with the standard
EN 60947-5-2
Acceleration
30g
Duration
11 ms
PSEN cs1.13p ATEX