PSEN 2.1p-24
Operating Manual PSEN 2.1p-24
21100-EN-13
| 17
Technical details
General
Certifications
ATEX, CE, EAC (Eurasian), ECOLAB, TÜV, cULus
Listed, electrosuisse
Sensor's mode of operation
Magnetic
Coding level in accordance with EN ISO 14119
Low
Design in accordance with EN ISO 14119
4
Classification in accordance with EN 60947-5-3
PDDB
Electrical data
Supply voltage
Voltage
24 V
Kind
DC
Voltage tolerance
-20 %/+20 %
Max. switching frequency
1 Hz
Lowest operating current (Im)
1 mA
Switching voltage
24 V
Internal resistance
100 Ohm
Max. switching current, safety contacts
10 mA
Max. breaking capacity, safety contacts
0,3 W
Max. permitted total power dissipation
170 mW
Times
Reaction time (actuator removed)
2 ms
Environmental data
ATEX certification
SEV 12 ATEX 0121 X
ATEX category, gas
II 3G Ex mc nAc IIC T6
ATEX category, dust
II 3D Ex mc tc IIIC T80°C
Application area
X: -25°C ≤ ta ≤ +55°C
Ambient temperature
Temperature range
-25 - 55 °C
Climatic suitability
In accordance with the standard
IEC 60068-2-30
Humidity
93 % r. h. at 40 °C
Max. operating height above sea level
2000 m
EMC
EN 60947-5-3
Vibration
In accordance with the standard
EN 60947-5-2
Frequency
10 - 55 Hz
Amplitude
1 mm
Shock stress
In accordance with the standard
EN 60947-5-2
Acceleration
30g
Duration
11 ms
Airgap creepage
Pollution degree
3