UL requirement: the supply voltage must be provided via a Class 2 power supply.
WARNING!
Ignition in a potentially explosive area!
Unintentionally removing the connector while voltage is applied may trigger
an explosion, causing serious injury and death.
– Switch off the supply voltage before removing the connector.
– Protect the connector from being removed unintentionally.
Pin assignment
NOTICE
The colour marking for the connection lead only applies for the cable that
Pilz supplies as an accessory
The safety switch is shown in an unoperated condition.
Assignment of the 4-pin connector
[1]
[2]
[3+]
[4]
white
brown
blue
black
Requirements and connection to evaluation devices
For use of PSEN 2.1p-24, ATEX in accordance with DIN EN 60947-5-3 an evaluation
device must be connected.
Connect the PSEN 2.1p-24, ATEX
}
either
with a certified Pilz evaluation device
}
or
with an evaluation device with defined properties
Certified Pilz evaluation devices are, for example:
}
PNOZelog for safety gate monitoring
– PNOZ e3.1p, PNOZ e3vp
– PNOZ e5.13p
}
PNOZmulti for safety gate monitoring
Configure the switch in the PNOZmulti Configurator with switch type 3.
}
PSS for safety gate monitoring with standard function block SB064, SB066 or
FS_Safety Gate
}