background image

PSEN 2.1p-24

Operating Manual PSEN 2.1p-24
21100-EN-13

| 19

Order reference

System

Product type

Features

Connection type

Order no.

PSEN 2.1p-24/

PSEN2.1-20/8mm/LED/

EX/1unit

Magnetic safety switch,

actuator round, with as-

sured operating distance

8 mm

4-pin M8 male connector

502 224

PSEN 2.1p-24 1switch ATEX

Magnetic safety switch

4-pin M8 male connector

522 124

PSEN 2.1-20/1actuator

Actuator round, with as-

sured operating distance

8 mm

512 120

Accessories

Cable

Product type

Connection 1

Connection 2

Length

Order no.

PSEN Kabel Winkel/cable

angleplug 2m

Female connector, M8

angled, 4-pin

Open cable end

2 m

533 110

PSEN Kabel Gerade /cable

straightplug2m

Female connector, M8

straight, 4-pin

2 m

533 111

PSEN Kabel Winkel/cable

angleplug 5m

Female connector, M8

angled, 4-pin

5 m

533 120

PSEN Kabel Gerade/cable

straightplug 5m

Female connector, M8

straight, 4-pin

5 m

533 121

PSEN Kabel Winkel/cable

angleplug 10m

Female connector, M8

angled, 4-pin

10 m

533 130

PSEN Kabel Gerade /cable

straightplug10m

Female connector, M8

straight, 4-pin

10 m

533 131

PSEN Kabel Winkel/cable

angleplug 3m

Female connector, M8

angled, 4-pin

30 m

533 140

PSEN Kabel Gerade /cable

straightplug30m

Female connector, M8

straight, 4-pin

30 m

533 141

PSS67 Cable M8sf M12sm Female connector, M8

straight, 4-pin

Male connector M12

straight

3 m

380 200

5 m

380 201

10 m

380 202

30 m

380 203

PSS67 Cable M8af M12sm Female connector M8

angled, 4-pin

3 m

380 204

5 m

380 205

10 m

380 206

30 m

380 207

Содержание PSEN 2.1p-24

Страница 1: ...PSEN 2 1p 24 Operating Manual 21100 EN 13 PSEN sensor technology...

Страница 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Страница 3: ...6 Disposal 6 For your safety 7 Unit features 7 Function description 8 Block diagram 8 Operating distances 8 Lateral and vertical offset 9 Wiring 9 Pin assignment 10 Requirements and connection to eva...

Страница 4: ...articularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive...

Страница 5: ...cordance with EN 60947 5 3 PDDB only in connection with the operator PSEN 2 1 20 and the suitable evaluation devices see Requirements and connection to evaluation devices 10 The following is deemed im...

Страница 6: ...evices systems and machines the person has to be informed of the state of the art and the applicable national European and international laws directives and standards It is the company s responsibilit...

Страница 7: ...bout to connect the unit This will prevent potential contamination The connector should be protected from accidental loosening e g using a cable tie WARNING Ignition spark from cable separator connect...

Страница 8: ...with the following components Actuator PSEN 2 1 20 see Order reference 19 and a connected evaluation device see Requirements and connection to evaluation devices 10 Block diagram Actuator Safety swit...

Страница 9: ...ngth lmax Rlmax Ri Rl km Imax Rlmax Max overall cable resistance see evaluation device s technical details Ri Internal resistance sensor see Technical details 17 Rl km Cable resistance km of the cable...

Страница 10: ...own in an unoperated condition Assignment of the 4 pin connector 1 2 3 4 white brown blue black Requirements and connection to evaluation devices For use of PSEN 2 1p 24 ATEX in accordance with DIN EN...

Страница 11: ...valuation device must fulfil the requirements in the Technical details 17 of PSEN 2 1p 24 ATEX Always comply with the max switching current safety contacts of PSEN 2 1p 24 ATEX Outputs at the evaluati...

Страница 12: ...uation devices Non Ex area Ex area I0 I1 PNOZmulti PSENmag 3 1 2 4 T1 T0 3 1 2 4 11 12 13 14 PSEN i1 brown white blue black Legend I0 Input OSSD I1 Input OSSD T1 T2 Test pulse outputs Non Ex area Ex a...

Страница 13: ...ts made of non magnetic material e g brass or stainless steel Avoid the risk of damages from foreseeable external influences by attaching the safety switch and actuator If necessary safety switch and...

Страница 14: ...eference Safety switches and actuators should only be secured using M4 screws with a flat head e g M4 cheese head or pan head screws Use screws made of non magnetic material e g brass Adjustment The s...

Страница 15: ...atmosphere Carry out a monthly function test on the safety switch and actuator Always test the function with the PSEN i1 interface and connected evaluation device The safety function may only be chec...

Страница 16: ...PSEN 2 1p 24 Operating Manual PSEN 2 1p 24 21100 EN 13 16 Dimensions in mm 13 6 5 13 8 5 36 22 6 8 4 5 26 10 6 M8x1 8 5 4 5 36 22 26 19 19...

Страница 17: ...nt safety contacts 10 mA Max breaking capacity safety contacts 0 3 W Max permitted total power dissipation 170 mW Times Reaction time actuator removed 2 ms Environmental data ATEX certification SEV 12...

Страница 18: ...0947 5 2 Yes follow installation guidelines Connection type M8 4 pin male connector Material Top PC Max torque setting Safety switch 1 Nm Actuator 1 1 Nm Dimensions Height 45 mm Width 26 mm Depth 13 m...

Страница 19: ...ade cable straightplug2m Female connector M8 straight 4 pin 2 m 533 111 PSEN Kabel Winkel cable angleplug 5m Female connector M8 angled 4 pin 5 m 533 120 PSEN Kabel Gerade cable straightplug 5m Female...

Страница 20: ...00 Series connection Product type Features Order no PSEN i1 Interface for 4 PSEN 2 Interface PSEN i1 for connecting and evaluating several safety switches PSEN ma 535 110 PDP67 F 8DI ION Decentralised...

Страница 21: ...fetyNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document d...

Отзывы: