9 Interfaces
Page
52
Installation manual PMCprimo Drive2
9.4 Feedback
9.4.1
Resolver connection (X2)
The motors of the PMCtendo AC1 and PMCtendo AC2 series have 2-pole hollow-shaft resolvers
built in as a standard. It is possible to connect 2...36-pole resolvers to the PMCprimo Drive2.
If lead lengths of more than 100m are planned, please contact our application department. The
thermostat contact in the motor is connected via the resolver cable to the PMCprimo Drive2 and
evaluated there.