14
Operation
Process
Data
Process data
START
XXXXXXXX
Reset contact monitoring
XXXXXXXX Dynamic: A braking process can be interrupted by opening
the reset contact
Static: A braking process cannot be interrupted again by
opening the start contact.
E-Halt
XXX
Braking with overtemperature
XXX
Off: A braking process is interrupted by overtemperature, the
brake goes into fault.
On: A braking process continues despite overtemperature,
after that the brake goes into fault.
E-Reset
XXXXXX
Error-reset
XXXXXX Auto: Fault is reset automatically
Manuel: Fault must be reset manually (press ESC and ENTER
simultaneously).
Slave
XXX
Master-Slave operation
XXX
Off: Stand-Alone-operation
On: Operation with Slave-brake (symmetrical braking)
ext.Temp
XXX
Motor temperature monitoring
XXX
Off: without motor temperature monitoring
On: The value of the connected PTC-thermistor at the
terminals Z31 and Z32 is monitored and if one of the internally
programmed thresholds is exceeded, the braking operation and
the motor enable are locked.
int.Temp
XXX°C
Heatsink limit temperature
XXX
Maximum heatsink in
o
C
Contrast
XXXX#
LCD contrast
XXXX
LCD contrast value, can be saved (retentive) in this menu