Overview
Operating Manual PSSu K F FAU B, PSSu K F FAU P
1003434-EN-05
| 7
2
Overview
PSENvip is a camera-based protection and measuring system (electrosensitive protective
equipment) for press brakes. It consists of a transmitter, receiver and a PSSu module to
evaluate recordings. It monitors the detection zone between the transmitter and receiver
below the moving upper tool. Operation, visualisation and configuration is via a web inter-
face on the CNC or control system driving the press.
[1]
[3]
[2]
Fig.: Components of the PSENvip
Receiver PSENvip R
[1]
}
Receives the light generated by the transmitter
}
Sends image date to the special module PSSu K F FAU
}
LED display for the status of the OSSD signal
Transmitter PSENvip E
[2]
}
Generates parallel beam
}
2 inputs for controlling the light source
Special module PSSu K F FAU [3]
}
Image evaluation of the data provided by the receiver
}
Evaluation of protected field and fast shutdown of the press if the protected field is viol-
ated
}
2 outputs to control the transmitter
}
Communication via Ethernet interface with the CNC
}
Troubleshooting and diagnostics
This operating manual describes
}
The module's inputs and outputs
}
The module interfaces
}
Access to the module's I/O data types
Module types described in the manual:
}
PSSu K F FAU-B: monitors a configured protected field for violation.
}
PSSu K F FAU-P: reduces the protected field dynamically during the press stroke (dy-
namic muting) and monitors this dynamic protected field for violation.