background image

ER2AC, ER4AC

Page 4.

2.2.1  Electrical connections

The IR-receiver shall be powered by 12-24 VDC/AC and shall only be connected to approved
powersupplies.

All connections shall be made without an active powersupply. The minimum cable area shall
be 0,22 mm

2

.

If necessary, it is possible to connect an additional IR-sensor to the IR-receiver. Also two IR-
receivers can be connected together, and work as IR-sensors for each other. An IR-signal will
be adducted to the other IR-receiver via the IR-bus. The IR-sensors have to be programmed
with the same user code. The IR-bus has 4 connections:
1.

 

IR-BUS signal.

2.

 

Ground (-).

3.

 

IR-BUS LED.

4.

 

=< + 24V.

To connect different receivers to each other, they have to use the same powersupply.

2.2.2 Wiring 

diagram

2.2.3  IR-receiver with lock-code

Picomeds IR-receivers are designed to work together with Abloy and Picomatic dooropeners.
Usually these advanced door-openers will be connected to only one relay-output. When the
IR-receiver is programmed with a lock-code signal, it will activate both relay 1 and 2. The
signal on output 2 will be activated a little bit before channel 1, and it is ment for lock-
systems which not can be controlled by the dooropener.

2.3 Programming

The ER2AC and ER4AC IR-receiver can be programmed by the 2 push-buttons next to the
LED on the PCB. It is also possible to use these buttons in combination with a
preprogrammed IR-transmitter and obtain a fast-mode programming. The front-cover has to
be removed to get access to the buttons. The power supply has to be connected to the IR-
receiver, but no electrical components shall be connected to the relay connections. The
receiver will not loose any settings during a power loss.

24 VDC
GND
IR
LED

RL1

RL2

RL4

RL3

ER4AC

24 VDC
GND
IR
LED

RL1

RL2

ER2AC

Содержание ER2AC

Страница 1: ...ndsheia 4993 Sundebru Tlf 47 3711 9950 Fax 47 3711 9951 E mail firmapost picomed no Foretaksnr 962 211 631 MVA Environmental Control Documentation for Picomed ER2AC and ER4AC IR receivers with 2 and 4 channels ...

Страница 2: ...3 2 2 1 Electrical connections 4 2 2 2 Wiring diagram 4 2 2 3 IR receiver with lock code 4 2 3 Programming 4 2 3 1 How to program the IR receiver 5 2 3 2 LED behaviour during programming mode 5 2 3 3 Programming memory 6 2 3 4 User code and channel programmed with buttons 6 2 3 5 User code and channel programmed with an IR remotecontroller 6 2 3 6 Lockcode programmed with buttons 7 2 3 7 Lockcode ...

Страница 3: ... not be covered by anything which can prevent the IR signals to reach it and it should not be exposed for direct sunlight 1 1 Water humidity and cleaning Picomed ER2AC and ER4AC is ment for indoor use Do not spell liquids on the receiver while it can destroy it 1 2 Cleaning It can be cleaned with a humid cloth alternatively use a mild soap 1 3 Malfunctioning Contact Name Telephonenumber 2 Technica...

Страница 4: ... IR receivers are designed to work together with Abloy and Picomatic dooropeners Usually these advanced door openers will be connected to only one relay output When the IR receiver is programmed with a lock code signal it will activate both relay 1 and 2 The signal on output 2 will be activated a little bit before channel 1 and it is ment for lock systems which not can be controlled by the doorope...

Страница 5: ... done by writing programming words PW which consists of sequences containing 0 and 1 The PW s should be written down before the programming starts to avoid any trouble due to timeouts during the programming If a wrong input is made press an hold the 0 button for 5 seconds to leave the PW and go back to programming mode without saving data There will be a timeout after 60 seconds if no keys are pre...

Страница 6: ... Usercode A4 A3 A2 A1 A0 0 0 0 0 0 0 0 1 1 0 0 0 0 1 2 2 0 0 0 1 0 3 3 0 0 0 1 1 0 4 0 0 1 0 0 1 5 0 0 1 0 1 2 6 0 0 1 1 0 3 7 0 0 1 1 1 0 8 0 1 0 0 0 1 9 0 1 0 0 1 2 10 0 1 0 1 0 3 11 0 1 0 1 1 0 12 0 1 1 0 0 1 13 0 1 1 0 1 2 14 0 1 1 1 0 3 15 0 1 1 1 1 0 16 1 0 0 0 0 1 17 1 0 0 0 1 2 18 1 0 0 1 0 3 19 1 0 0 1 1 0 20 1 0 1 0 0 1 21 1 0 1 0 1 2 22 1 0 1 1 0 3 23 1 0 1 1 1 0 24 1 1 0 0 0 1 25 1 1 0...

Страница 7: ...X Press and hold the 0 button for 5 seconds and let off the button when the LED lit Press the 0 button once the LED will start flashing rapidly Enter the 12 bit lockcode to be used The LED will flash twice Finish by press hold the 0 buttons for 5 seconds 2 3 7 Lockcode programmed with an IR remote controller A fast mode programming mode is also available A preprogrammed IR remote controller can be...

Страница 8: ...codes They can read the following IR formats New Assistant 32 usercodes with 16 channels in each New Assistant lockcode 12 bit Gewa Infralink 4 groups with 16 channels in each Gewa Infralink lockcode old 10 bit Gewa Infralink lockcode new12 bit The IR receiver can be programmed to respond on both New Assistant and Gewa if needed ER2AC has 2 channels relays ER4AC has 4 channels relays Each relay ou...

Страница 9: ...ntrol Number of channels 2 4 potential free relays 0 5 A 48 Volt Powersupply External powersupply 9 24 VAC DC Current consumption 50 mA Temperature 10 up to 40 C Connections Internal screw terminals Weight Ca 100 g Materiale Plastic Settings Usercode Channel Lockcode Relay working mode Neccessary depth when flush mounting 35 mm ...

Страница 10: ...exposed by sunshine The IR sensor is defect and has to be changed Call Your technichian The receiver does not work when the sun is shining on it It has to be moved to a place where it not is exposed by sunshine Call Your technichian The receiver is connected to a common door and works only for some users Not correct programmed Check the user manual Call Your technichian The receiver works somethim...

Страница 11: ......

Отзывы: