Page 1.2
MATRIX MODULE 40-510/511/512/513
pickering
SECTION 1 - TECHNICAL SPECIFICATION
pickering
test
.com
Switching Specification
Switch Type:
Ruthenium Reed
Max Switch Voltage:
150VDC/100VAC
Max Power:
Max Switch Current:
Max Carry Current:
20W
1A
1.2A
Initial Path Resistance
On (single module):
Off (single module):
Differential Thermal Offset:
<600m
Ω
(40-510/511)
<1000m
Ω
(40-512)
<800m
Ω
(40-513)
>10
9
Ω
<15µV
Operate Time:
Release Time:
<0.5ms, 0.25ms typical
<0.5ms, 0.25ms typical
Expected Life
Low power load:
Full power load:
1x10
9
operations
>5x10
6
operations
Isolation and Crosstalk (screened reed versions)
Crosstalk @1MHz:
@10MHz:
@25MHz:
62dB (typical)
42dB (typical)
40dB (typical)
Isolation @1MHz:
@10MHz:
@25MHz:
65dB (typical)
49dB (typical)
45dB (typical)
Product Order Codes
Single 12x4 Matrix, 1-Pole
40-510-021
Single 12x4 Matrix, 2-Pole
40-510-022
Dual 12x4 Matrix, 1-Pole
40-511-021
Dual 12x4 Matrix, 2-Pole
40-511-022
Single 12x8 Matrix, 1-Pole
40-512-021
Single 12x8 Matrix, 2-Pole
40-512-022
Single 24x4 Matrix, 1-Pole
40-513-021
Single 24x4 Matrix, 2-Pole
40-513-022
Options
–S
All 1-pole versions are available with screened reed
relays (e.g. 40-512-021-S)
Power Requirements
+3.3V
+5V
+12V
-12V
0
400mA (typ 280mA)
0
0
Mechanical Characteristics
Single slot 3U PXI (CompactPCI card).
Module weight: 280g (40-513-021)
260g (40-513-022)
3D models for all versions in a variety of popular file formats
are available on request.
Connectors
PXI bus via 32-bit P1/J1 backplane connector.
Signals via front panel 68-pin female micro-D connector, pin
outs are in the operating manual.
PCB Layout for the 40-510 Matrix Module
Mating Connectors & Cabling
For connection accessories for the 40-510 series
please refer to the
90-015D
68-pin micro-D Connector
Accessories data sheet where a complete list and
documentation can be found for accessories, or refer to the
Connection Solutions catalog.
Support Products
eBIRST Switching System Test Tool
This product is supported by the eBIRST test tools which
simplify the identification of failed relays, the required
eBIRST tools are below. For more information see
Product
Test Tool
Adapter
All Types
93-006-001
93-006-401
Spare Relay Kits
Kits of replacement relays are available for the majority of
Pickering’s PXI switching products, simplifying servicing and
reducing down-time.
Product
Relay Kit
40-510-021
91-100-003
40-510-021-S 91-100-011
40-510-022
91-100-008
40-511-021
91-100-003
40-511-021-S 91-100-011
40-511-022
91-100-008
40-512-021
91-100-003
40-512-021-S 91-100-011
40-512-022
91-100-008
40-513-021
91-100-003
40-513-021-S 91-100-011
40-513-022
91-100-008
For further assistance, please contact your local Pickering
sales office.
Содержание PXI 40-510
Страница 6: ...Page VI MATRIX MODULE 40 510 511 512 513 pickering THIS PAGE INTENTIONALLY BLANK...
Страница 8: ...Page VIII MATRIX MODULE 40 510 511 512 513 pickering THIS PAGE INTENTIONALLY BLANK...
Страница 18: ...Page 3 4 MATRIX MODULE 40 510 511 512 513 pickering SECTION 3 INSTALLATION THIS PAGE INTENTIONALLY BLANK...
Страница 32: ...MATRIX MODULE 40 510 511 512 513 Page 6 2 pickering SECTION 6 TROUBLE SHOOTING THIS PAGE INTENTIONALLY BLANK...