Page 4.5
MATRIX MODULE 40-510/511/512/513
pickering
SECTION 4 - PROGRAMMING GUIDE
MODULE ARCHITECTURE 40-512
One sub-unit is used to control all the module’s relays as shown below. Enabling a particular bit or crosspoint closes
the contacts of that relay and creates a signal path. For 2-pole versions, both poles are closed simultaneously.
40-512-022 12x8 Matrix
(96 x DPST)
Sub-Unit OpBit
Bit
OpCrosspoint
(Row,Column)
40-512-021 Signal Path
(with relay energised)
1
1
1,1
X1 to Y1
1
2
1,2
X2 to Y1
1
3
1,3
X3 to Y1
1
4
1,4
X4 to Y1
1
5
1,5
X5 to Y1
1
6
1,6
X6 to Y1
1
7
1,7
X7 to Y1
1
8
1,8
X8 to Y1
1
9
1,8
X9 to Y1
1
10
1,10
X10 to Y1
1
11
1,11
X11 to Y1
1
12
1,12
X12 to Y1
1
13
2,1
X1 to Y2
1
14
2,2
X2 to Y2
1
15
2,3
X3 to Y2
1
16
2,4
X4 to Y2
1
17
2,5
X5 to Y2
1
18
2,6
X6 to Y2
1
19
2,7
X7 to Y2
1
20
2,8
X8 to Y2
1
21
2,9
X9 to Y2
1
22
2,10
X10 to Y2
1
23
2,11
X11 to Y2
1
24
2,12
X12 to Y2
1
25
3,1
X1 to Y3
1
26
3,2
X2 to Y3
1
27
3,3
X3 to Y3
1
28
3,4
X4 to Y3
1
29
3,5
X5 to Y3
1
30
3,6
X6 to Y3
1
31
3,7
X7 to Y3
1
32
3,8
X8 to Y3
1
33
3,9
X9 to Y3
1
34
3,10
X10 to Y3
1
35
3,11
X11 to Y3
1
36
3,12
X12 to Y3
1
37
4,1
X1 to Y4
1
38
4,2
X2 to Y4
1
39
4,3
X3 to Y4
1
40
4,4
X4 to Y4
1
41
4,5
X5 to Y4
1
42
4,6
X6 to Y4
1
43
4,7
X7 to Y4
1
44
4,8
X8 to Y4
1
45
4,9
X9 to Y4
1
46
4,10
X10 to Y4
1
47
4,11
X11 to Y4
1
48
4,12
X12 to Y4
The 40-512-021 is an array of 96 single pole relays, and the 40-512-022 an array of 96 double pole relays. In the
default state all relays are open circuit. Energising a particular relay creates a signal path between its C and A
terminals. The 40-512-022 module’s switching architecture is shown in its default state in the diagram below:
Sub-Unit OpBit
Bit
OpCrosspoint
(Row,Column)
40-512-021 Signal Path
(with relay energised)
1
49
5,1
X1 to Y5
1
50
5,2
X2 to Y5
1
51
5,3
X3 to Y5
1
52
5,4
X4 to Y5
1
53
5,5
X5 to Y5
1
54
5,6
X6 to Y5
1
55
5,7
X7 to Y5
1
56
5,8
X8 to Y5
1
57
5,9
X9 to Y5
1
58
5,10
X10 to Y5
1
59
5,11
X11 to Y5
1
60
5,12
X12 to Y5
1
61
6,1
X1 to Y6
1
62
6,2
X2 to Y6
1
63
6,3
X3 to Y6
1
64
6,4
X4 to Y6
1
65
6,5
X5 to Y6
1
66
6,6
X6 to Y6
1
67
6,7
X7 to Y6
1
68
6,8
X8 to Y6
1
69
6,9
X9 to Y6
1
70
6,10
X10 to Y6
1
71
6,11
X11 to Y6
1
72
6,12
X12 to Y6
1
73
7,1
X1 to Y7
1
74
7,2
X2 to Y7
1
75
7,3
X3 to Y7
1
76
7,4
X4 to Y7
1
77
7,5
X5 to Y7
1
78
7,6
X6 to Y7
1
79
7,7
X7 to Y7
1
80
7,8
X8 to Y7
1
81
7,9
X9 to Y7
1
82
7,10
X10 to Y7
1
83
7,11
X11 to Y7
1
84
7,12
X12 to Y7
1
85
8,1
X1 to Y8
1
86
8,2
X2 to Y8
1
87
8,3
X3 to Y8
1
88
8,4
X4 to Y8
1
89
8,5
X5 to Y8
1
90
8,6
X6 to Y8
1
91
8,7
X7 to Y8
1
92
8,8
X8 to Y8
1
93
8,9
X9 to Y8
1
94
8,10
X10 to Y8
1
95
8,11
X11 to Y8
1
96
8,12
X12 to Y8
X2
X4
X8
X1
X3
X5
X6
X7
X9
X10
Y2
Y4
Y8
Y1
Y3
Y5
Y6
Y7
X11
X12
2-
PO
LE
CR
OS
SP
OI
NT
A1
C1
A2
C2
DPST Relay contacts
Содержание PXI 40-510
Страница 6: ...Page VI MATRIX MODULE 40 510 511 512 513 pickering THIS PAGE INTENTIONALLY BLANK...
Страница 8: ...Page VIII MATRIX MODULE 40 510 511 512 513 pickering THIS PAGE INTENTIONALLY BLANK...
Страница 18: ...Page 3 4 MATRIX MODULE 40 510 511 512 513 pickering SECTION 3 INSTALLATION THIS PAGE INTENTIONALLY BLANK...
Страница 32: ...MATRIX MODULE 40 510 511 512 513 Page 6 2 pickering SECTION 6 TROUBLE SHOOTING THIS PAGE INTENTIONALLY BLANK...