Page 4.4
MATRIX MODULE 40-510/511/512/513
pickering
SECTION 4 - PROGRAMMING GUIDE
X102
X104
X108
X101
X103
X105
X106
X107
X109
X110
Y102
Y104
Y101
Y103
X202
X204
X208
X201
X203
X205
X206
X207
X209
X210
Y202
Y204
Y201
Y203
X111
X112
X211
X212
MA
TR
IX
CR
OS
SP
OI
NT
MODULE ARCHITECTURE 40-511
Two sub-units are used to control the module’s relays as shown below. Enabling a particular bit or crosspoint closes
the contacts of that relay and creates a signal path. For 2-pole versions, both poles are closed simultaneously.
40-511-021
Dual 12x4 Matrix
(96 x SPST)
Sub-Unit OpBit
Bit
OpCrosspoint
(Row,Column)
40-511-021 Signal Path
(with relay energised)
1
1
1,1
X101 to Y101
1
2
1,2
X102 to Y101
1
3
1,3
X103 to Y101
1
4
1,4
X104 to Y101
1
5
1,5
X105 to Y101
1
6
1,6
X106 to Y101
1
7
1,7
X107 to Y101
1
8
1,8
X108 to Y101
1
9
1,9
X109 to Y101
1
10
1,10
X110 to Y101
1
11
1,11
X111 to Y101
1
12
1,12
X112 to Y101
1
13
2,1
X101 to Y102
1
14
2,2
X102 to Y102
1
15
2,3
X103 to Y102
1
16
2,4
X104 to Y102
1
17
2,5
X105 to Y102
1
18
2,6
X106 to Y102
1
19
2,7
X107 to Y102
1
20
2,8
X108 to Y102
1
21
2,9
X109 to Y102
1
22
2,10
X110 to Y102
1
23
2,11
X111 to Y102
1
24
2,12
X112 to Y102
1
25
3,1
X101 to Y103
1
26
3,2
X102 to Y103
1
27
3,3
X103 to Y103
1
28
3,4
X104 to Y103
1
29
3,5
X105 to Y103
1
30
3,6
X106 to Y103
1
31
3,7
X107 to Y103
1
32
3,8
X108 to Y103
1
33
3,9
X109 to Y103
1
34
3,10
X110 to Y103
1
35
3,11
X111 to Y103
1
36
3,12
X112 to Y103
1
37
4,1
X101 to Y104
1
38
4,2
X102 to Y104
1
39
4,3
X103 to Y104
1
40
4,4
X104 to Y104
1
41
4,5
X105 to Y104
1
42
4,6
X106 to Y104
1
43
4,7
X107 to Y104
1
44
4,8
X108 to Y104
1
45
4,9
X109 to Y104
1
46
4,10
X110 to Y104
1
47
4,11
X111 to Y104
1
48
4,12
X112 to Y104
The 40-511-021 is an array of 96 single pole relays, and the 40-511-022 an array of 96 double pole relays. In the
default state all relays are open circuit. Energising a particular relay creates a signal path between its C and A
terminals. The 40-511-021 module’s switching architecture is shown in its default state in the diagram below:
Sub-Unit OpBit
Bit
OpCrosspoint
(Row,Column)
40-511-021 Signal Path
(with relay energised)
2
1
1,1
X201 to Y201
2
2
1,2
X202 to Y201
2
3
1,3
X203 to Y201
2
4
1,4
X204 to Y201
2
5
1,5
X205 to Y201
2
6
1,6
X206 to Y201
2
7
1,7
X207 to Y201
2
8
1,8
X208 to Y201
2
9
1,9
X209 to Y201
2
10
1,10
X210 to Y201
2
11
1,11
X211 to Y201
2
12
1,12
X212 to Y201
2
13
2,1
X201 to Y202
2
14
2,2
X202 to Y202
2
15
2,3
X203 to Y202
2
16
2,4
X204 to Y202
2
17
2,5
X205 to Y202
2
18
2,6
X206 to Y202
2
19
2,7
X207 to Y202
2
20
2,8
X208 to Y202
2
21
2,9
X209 to Y202
2
22
2,10
X210 to Y202
2
23
2,11
X211 to Y202
2
24
2,12
X212 to Y202
2
25
3,1
X201 to Y203
2
26
3,2
X202 to Y203
2
27
3,3
X203 to Y203
2
28
3,4
X204 to Y203
2
29
3,5
X205 to Y203
2
30
3,6
X206 to Y203
2
31
3,7
X207 to Y203
2
32
3,8
X208 to Y203
2
33
3,9
X209 to Y203
2
34
3,10
X210 to Y203
2
35
3,11
X211 to Y203
2
36
3,12
X212 to Y203
2
37
4,1
X201 to Y204
2
38
4,2
X202 to Y204
2
39
4,3
X203 to Y204
2
40
4,4
X204 to Y204
2
41
4,5
X205 to Y204
2
42
4,6
X206 to Y204
2
43
4,7
X207 to Y204
2
44
4,8
X208 to Y204
2
45
4,9
X209 to Y204
2
46
4,10
X210 to Y204
2
47
4,11
X211 to Y204
2
48
4,12
X212 to Y204
A1
C1
SPST Relay contacts
Содержание PXI 40-510
Страница 6: ...Page VI MATRIX MODULE 40 510 511 512 513 pickering THIS PAGE INTENTIONALLY BLANK...
Страница 8: ...Page VIII MATRIX MODULE 40 510 511 512 513 pickering THIS PAGE INTENTIONALLY BLANK...
Страница 18: ...Page 3 4 MATRIX MODULE 40 510 511 512 513 pickering SECTION 3 INSTALLATION THIS PAGE INTENTIONALLY BLANK...
Страница 32: ...MATRIX MODULE 40 510 511 512 513 Page 6 2 pickering SECTION 6 TROUBLE SHOOTING THIS PAGE INTENTIONALLY BLANK...