Page 4.4
HIGH DENSITY RELAY MODULES 40-145/146/148
pickering
SECTION 4 - PROGRAMMING GUIDE
MODULE ARCHITECTURE - 40-145 NORMALLY CLOSED VERSIONS
One sub-unit is used to control all the module’s relays as shown below. Enabling a particular bit disconnects the C
to B signal path.
40-145-001-NC
(50 x SPST)
The 40-145-001/101/201-NC are arrays of 50, 75 or 100 uncommitted SPST relays. In the default state, all signal
paths are connected between the C and the corresponding B terminals, energising a particular relay disconnects
the signal path The relay module’s switching architectures are shown in their default state in the diagram below:
40-145-101-NC
(75 x SPST)
B50
C50
B2
C2
B1
C1
B100
C100
B4
C4
B3
C3
B2
C2
B1
C1
B75
C75
B3
C3
B2
C2
B1
C1
Sub-Unit
Bit
40-145-001-NC Signal Path
(with relay de-energised)
40-145-101-NC Signal Path
(with relay de-energised)
40-145-201-NC Signal Path
(with relay de-energised)
1
1
C1 to B1
C1 to B1
C1 to B1
1
2
C2 to B2
C2 to B2
C2 to B2
1
3
C3 to B3
C3 to B3
C3 to B3
1
4
C4 to B4
C4 to B4
C4 to B4
1
49
C49 to B49
C49 to B49
C49 to B49
1
50
C50 to B50
C50 to B50
C50 to B50
1
51
—
C51 to B51
C51 to B51
1
52
—
C52 to B52
C52 to B52
1
74
—
C74 to B74
C74 to B74
1
75
—
C75 to B75
C75 to B75
1
76
—
—
C76 to B76
1
77
—
—
C77 to B77
1
97
—
—
C97 to B97
1
98
—
—
C98 to B98
1
99
—
—
C99 to B99
1
100
—
—
C100 to B100
40-145-201-NC
(100 x SPST)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com