Page 4.5
HIGH DENSITY RELAY MODULES 40-145/146/148
pickering
SECTION 4 - PROGRAMMING GUIDE
MODULE ARCHITECTURE - 40-146
One sub-unit is used to control all the module’s relays as shown below. Enabling a particular bit closes both C to A
signal paths of the corresponding channel.
40-146-002 (25 x DPST)
The 40-146 is an array of 25 or 50 uncommitted DPST relays. In the default state, all signal paths are open.
Energising a particular relay creates a signal path between the C and A terminals of both poles of the corresponding
channel. The relay module’s switching architectures are shown in their default state in the diagram below:
40-146-202 (50 x DPST)
A1.2
C1.2
A1.1
C1.1
A25.2
C25.2
A25.1
C25.1
A1.2
C1.2
A1.1
C1.1
A2.2
C2.2
A2.1
C2.1
A50.2
C50.2
A50.1
C50.1
Sub-Unit
Bit
40-146-002 Signal Path
(with relay energised)
40-146-202 Signal Path
(with relay energised)
1
1
C1.1 to A1.1 & C1.2 to A1.2
C1.1 to A1.1 & C1.2 to A1.2
1
2
C2.1 to A2.1 & C2.2 to A2.2
C2.1 to A2.1 & C2.2 to A2.2
1
3
C3.1 to A3.1 & C3.2 to A3.2
C3.1 to A3.1 & C3.2 to A3.2
1
4
C4.1 to A4.1 & C4.2 to A4.2
C4.1 to A4.1 & C4.2 to A4.2
1
24
C24.1 to A24.1 & C24.2 to A24.2
C24.1 to A24.1 & C24.2 to A24.2
1
25
C25.1 to A25.1 & C25.2 to A25.2
C25.1 to A25.1 & C25.2 to A25.2
1
26
—
C26.1 to A26.1 & C26.2 to A26.2
1
27
—
C27.1 to A27.1 & C27.2 to A27.2
1
47
—
C47.1 to A47.1 & C47.2 to A47.2
1
48
—
C48.1 to A48.1 & C48.2 to A48.2
1
49
—
C49.1 to A49.1 & C49.2 to A49.2
1
50
—
C50.1 to A50.1 & C50.2 to A50.2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com