Page 4.6
HIGH DENSITY RELAY MODULES 40-145/146/148
pickering
SECTION 4 - PROGRAMMING GUIDE
MODULE ARCHITECTURE - 40-148
One sub-unit is used to control all the module’s relays as shown below. Enabling a particular bit opens the C to B
signal path and closes the C to A signal path.
40-148-001 (32 x SPDT)
The 40-148 is an array of 32, 48 or 64 uncommitted changeover relays. In the default state, all signal paths are
between the C terminal and the corresponding B terminal. Energising a particular relay disconnects the B terminal
and creates a signal path between the C and A terminals. The relay module’s switching architectures are shown in
their default state in the diagram below:
40-148-101 (48 x SPDT)
B32
A32
C32
B1
A1
C1
B1
A1
C1
B2
A2
C2
B64
A64
C64
B3
A3
C3
B1
A1
C1
B48
A48
C48
B2
A2
C2
40-148-201 (64 x SPDT)
Sub-Unit
Bit
40-148-001 Signal Path
(with relay energised)
40-148-101 Signal Path
(with relay energised)
40-148-201 Signal Path
(with relay energised)
1
1
C1 to A1
C1 to A1
C1 to A1
1
2
C2 to A2
C2 to A2
C2 to A2
1
3
C3 to A3
C3 to A3
C3 to A3
1
4
C4 to A4
C4 to A4
C4 to A4
1
31
C31 to A31
C31 to A31
C31 to A31
1
32
C32 to A32
C32 to A32
C32 to A32
1
33
—
C33 to A33
C33 to A33
1
34
—
C34 to A34
C34 to A34
1
47
—
C47 to A47
C47 to A47
1
48
—
C48 to A48
C48 to A48
1
49
—
—
C49 to A49
1
50
—
—
C50 to A50
1
61
—
—
C61 to A61
1
62
—
—
C62 to A62
1
63
—
—
C63 to A63
1
64
—
—
C64 to A64