9 - 100
Fuel injection
To control the circuit, proceed as follows:
Connect the diagnosis tester 020460Y
see page 9-17.
Set ignition to "ON" with switch in position "RUN"
and side stand raised.
Select the “ERRORS “ function from the menu
Check if the control unit has registered anomalies
concerning the electrical ventilation control circuit.
NO
YES
Select the “ACTIVE DIAGNOSIS“
function from the menu
Activate the electrical fan
diagnosis function
Check acoustically the electrical
fan rotation.
Await the results from the
diagnosis tester.
Test completed successfully.
The fan rotates.
NO
YES
The electrical ventilation system conforms.
Test failed.
The fan does not rotate.
NO
Test completed successfully.
The fan has not worked.
The electromagnetic switch control circuit is efficient.
Check the electrical fan connection, electromagnetic switch contact efficiency,
positive wires, negative wire and the electrical fan motor.
Содержание 500 cc
Страница 4: ...TABLE OF CONTENTS GENERAL INFORMATION AND MAINTENANCE 1...
Страница 12: ...TABLE OF CONTENTS SPECIFIC TOOLING 2...
Страница 15: ...TABLE OF CONTENTS AUTOMATIC TRANSMISSION 3...
Страница 32: ...TABLE OF CONTENTS FINAL REDUCTION 4...
Страница 34: ...TABLE OF CONTENTS FLYWHEEL COVER 5...
Страница 51: ...TABLE OF CONTENTS FLYWHEEL AND STARTING SYSTEM 6...
Страница 63: ...TABLE OF CONTENTS THERMAL UNIT AND TIMING SYSTEM 7...
Страница 94: ...TABLE OF CONTENTS CRANKCASE AND DRIVING SHAFT 8...
Страница 113: ...TABLE OF CONTENTS FUEL INJECTION 9...
Страница 220: ...TABLE OF CONTENTS LUBRICATION 10...
Страница 228: ...TABLE OF CONTENTS COOLING SYSTEM 11...
Страница 236: ...TABLE OF CONTENCTS STARTING 12...