5 Installation
20
Version: 1.1.1
MP160E
V-551 Linear Stage
Mounting option
Mounting holes, details see "Dimensions" (p. 50)
Mounting from below
using four M6 screws
This mounting option is
used for example, when
setting up an XY system
and the upper stage is a
V-551.7D (p. 24).
Figure 7: Mounting the V-551 from below with four M6 screws; here:
V-551.7D. The position of the M6 holes with a depth of 8 mm is
different for the V-551 models
Requirements
You have read and understood the general notes on installation (p. 15).
The V-551 is
not
connected to the controller.
You have provided a suitable surface (for the required position and depth of the holes
for accommodating the screws, see "Dimensions" (p. 50)):
−
For mounting from above: Four M6 or M4 threaded holes are provided.
−
For mounting from below: Four Ø 6.4 mm through holes are provided.
−
For applications with large temperature changes: The surface should have the same
thermal expansion properties as the V-551 (e.g., surface made of aluminum).
−
The flatness of the surface is ≤20
µm.