background image

 

 

 

 

 

 

 

www.phywe.com, © All rights reserved 

 

12620-09 and 12620-10 / 2715

 

Operating instructions 

 

 

Fig. 1: Cobra4 Mobile-Link 2 

Cobra4 Mobile-Link 2 

(Cobra4 Mobile-Link 2 incl. accessories) 

12620-09 

(12620-10) 

PHYWE Systeme GmbH & Co. KG 
Robert-Bosch-Breite 10 
37079 Göttingen 
Germany 
 
Phone 

+49

 (0) 551 604-0 

Fax   

+49

 (0) 551 604-107 

E-mail 

[email protected] 

Internet 

www.phywe.com 

 

 

 

The unit complies 
with the applicable 
EC-guidelines 

 

 

TABLE OF CONTENTS 

1

 

SAFETY PRECAUTIONS

 

2

 

PURPOSE AND CHARACTERISTICS

 

3

 

FUNCTIONAL AND OPERATING ELEMENTS

 

3.1

 

Operating elements on the top

 

3.2

 

Sensor interface

 

3.3

 

Recording function of the memory card

 

4

 

NOTES ON OPERATION

 

5

 

MOBILE HANDLING

 

5.1

 

Start-up

 

5.2

 

Starting the unit

 

5.3

 

Measurement data recording process

 

5.4.1

 

Sensor/Range (1.1)

 

5.4.2

 

Sensor > Setup (1.2)

 

5.4.3

 

Datalogger/Setup (2.1)

 

5.4.4

 

Datalogger/Files (2.2)

 

5.4.5

 

Zero (3)

 

5.4.6

 

Calibration (4)

 

5.4.7

 

Setup/Date/Time (5.1)

 

5.4.8

 

Setup/Battery status (5.2)

 

5.4.10

 

Setup/Information (5.4)

 

5.4.11

 

Setup/Large Display (5.5)

 

5.4.12

 

Utilities/Stopwatch (6.1)

 

5.4.13

 

Utilities/Water level (6.2)

 

5.4.14

 

Extras/ GPS (6.3)

 

6

 

HANDLING VIA A PC

 

6.1 Start-up

 

6.2 Starting the unit

 

7

 

CHANGING THE BATTERY

 

8

 

TECHNICAL DATA

 

9

 

PARTS SUPPLIED

 

10

 

ACCESSORIES

 

11

 

WARRANTY

 

12

 

WASTE DISPOSAL

 

 

 
 

1

 

SAFETY PRECAUTIONS 

 

-

 

Read  the  operating  instructions  thoroughly  and  com-
pletely prior to starting the unit. This is important for your 
own protection and for avoiding damage to the unit. 

-

 

Use the unit solely for its intended purpose. 

-

 

The  unit  is  intended  solely  for  use  in  dry  rooms  where 
there is no risk of explosion. 

-

 

Protect  the  device  against  dust,  moisture,  and  vapours. 
Clean the unit with a slightly moist, lint-free cloth. Do not 
use any aggressive cleaning agents or solvents. 

Attention! 

Содержание 12620-09

Страница 1: ...nsor Setup 1 2 5 4 3 Datalogger Setup 2 1 5 4 4 Datalogger Files 2 2 5 4 5 Zero 3 5 4 6 Calibration 4 5 4 7 Setup Date Time 5 1 5 4 8 Setup Battery status 5 2 5 4 10 Setup Information 5 4 5 4 11 Setup...

Страница 2: ...supply unit 3 FUNCTIONAL AND OPERATING ELEMENTS 3 1 Operating elements on the top The Cobra4 Mobile Link 2 is equipped with various elements for the measurement data display operation and status indi...

Страница 3: ...nity of the unit After a complete shut down of the unit it must be switched off and on again by way of the ON OFF switch operating ele ment If the unit does not react keep the ON OFF switch pressed fo...

Страница 4: ...performed up to three times 5 3 Measurement data recording process A measurement can be started and stopped by pressing the confirmation key The measurement data recording proc ess is indicated by a...

Страница 5: ...The file name consists of the date and a running counter YYMMDDxx mli xx 00 99 Ensure that the date and time are set in the Cobra4 Mobile Link This can be checked and if needed changed in the Setup m...

Страница 6: ...Unit Conductivity 12632 00 It enables the automatic temperature compensation of a pH or conductivity measuring channel e g T 1 with regard to a temperature input or the manual input of a known temper...

Страница 7: ...e following Cobra4 Sen sor Units Cobra4 Sensor Unit Radioactivity 12665 00 It is used to change the counter tube voltage in order to measure the counter tube characteristics Gate time This setting opt...

Страница 8: ...imer Counter 12651 00 5 4 3 Datalogger Setup 2 1 The following changes are possible Selection of the single value measurement mode by way of a switch This ensures that only one value will be re corded...

Страница 9: ...u item enables the measurement values of the measuring channels to be manually reset to zero To do so the switches of the desired channels are set from off to on by way of the arrow keys Fig 20 You ca...

Страница 10: ...played in the header The automatic rotation of the device display can be switched on and off Use the confirmation key in order to confirm a new setting 5 4 10 Setup Information 5 4 Here you can find g...

Страница 11: ...es minutes and seconds This menu item can only be used in combination with a Mo bile Link 2 GPS 12620 20 and GPS activated See also chapter 5 4 9 Coordinates will not be displayed unless satellites ha...

Страница 12: ...f the battery decreases strongly it is possible to change the battery Please note that damage resulting from a battery change are not covered by the warranty You can send the Mobile Link to the repair...

Страница 13: ...Unit Energy 12656 00 Cobra4 Sensor Unit Forceplate 12661 00 Cobra4 Sensor Unit Radioactivity 12665 00 Cobra4 Sensor Unit Sound Level 12669 00 Cobra4 Sensor Unit Weather air pressure humidity temperatu...

Отзывы: