6.2 Starting the unit  

Prior  to  connecting  the  unit  to  the  PC,  attach  the  desired 
Cobra4  Sensor-Unit  to  it.  Following  the  connection  of  the 
device  to  the  PC  via  the  USB  port,  the  connection  is  con-
firmed  visually  on  the  display  of  the  Cobra4  Mobile-Link 2 
(Fig. 29). 

The  upper  area  of  the  display  shows  the  sensor  that  has 
been  identified  as  well  as  the  device  number  (if  several  Co-
bra4  devices  are  connected  via  the  USB  interface,  they  are 
numbered).  In  the  upper  right-hand  corner,  a  measurement 
that  is  started  via  the  PC  is  indicated  by  the  recording  sym-
bol 

Once the connection has been set up, Cobra4 Mobile-Link 2 
and the connected Sensor-Unit are automatically displayed in 
the  "measure"  software  together  with  all  of  the  measuring 
channels.  All  further  steps,  such  as  the  recording  of  meas-
urement values or changing of the measurement parameters, 
are  software-based  and,  therefore,  not  described  in  this 
document. 

7

 

CHANGING THE BATTERY 

If the capacity of the battery decreases strongly, it is possible 
to  change  the  battery.  Please  note  that  damage  resulting 
from a battery change are not covered by the warranty. You 
can  send  the  Mobile-Link  to  the  repairs  department  of 
PHYWE in order to have the battery changed. 
 

 

 
Step 1: Open the battery cover by pressing a pen or another 
object onto the holder of the battery cover.  

Attention

: Open the left-hand side first, followed by the right-

hand side, in order to ensure that the flat cable connector that 
is located on the left of the battery is not damaged. 
 

 

 

 

 
Step 2:  Disconnect  the  battery  connector  from  the  circuit 
board. Remove the old battery. Insert the new battery into the 
holder. 
 

 

 
Step 3: Connect the connector of the new battery.   

Attention

:  Ensure  that  the  cable  is  located  above  the  USB 

connector or, otherwise, the cover cannot be closed. 

TECHNICAL DATA 

typical for 25

 °C: 

Operating temperature range  

5

–40 °C 

Relative humidity 

< 80

 % 

 

Device  for  mobile  data  acquisition  and  storage  with  a  USB 
interface for the data transfer to a PC 

 

Power supply

 

integrated lithium-ion 
battery 

1950 mAh 

Data memory

 

SD/MMC 

Data rate (max.)

 

2

 kHz in combination

 

with 

a PC 

Dimensions (L

 x W x H)

 

155

 mm x 65 mm x 35 mm 

Mass

 

200

 g 

Battery life 

up to 6

 h 

Содержание 12620-09

Страница 1: ...nsor Setup 1 2 5 4 3 Datalogger Setup 2 1 5 4 4 Datalogger Files 2 2 5 4 5 Zero 3 5 4 6 Calibration 4 5 4 7 Setup Date Time 5 1 5 4 8 Setup Battery status 5 2 5 4 10 Setup Information 5 4 5 4 11 Setup...

Страница 2: ...supply unit 3 FUNCTIONAL AND OPERATING ELEMENTS 3 1 Operating elements on the top The Cobra4 Mobile Link 2 is equipped with various elements for the measurement data display operation and status indi...

Страница 3: ...nity of the unit After a complete shut down of the unit it must be switched off and on again by way of the ON OFF switch operating ele ment If the unit does not react keep the ON OFF switch pressed fo...

Страница 4: ...performed up to three times 5 3 Measurement data recording process A measurement can be started and stopped by pressing the confirmation key The measurement data recording proc ess is indicated by a...

Страница 5: ...The file name consists of the date and a running counter YYMMDDxx mli xx 00 99 Ensure that the date and time are set in the Cobra4 Mobile Link This can be checked and if needed changed in the Setup m...

Страница 6: ...Unit Conductivity 12632 00 It enables the automatic temperature compensation of a pH or conductivity measuring channel e g T 1 with regard to a temperature input or the manual input of a known temper...

Страница 7: ...e following Cobra4 Sen sor Units Cobra4 Sensor Unit Radioactivity 12665 00 It is used to change the counter tube voltage in order to measure the counter tube characteristics Gate time This setting opt...

Страница 8: ...imer Counter 12651 00 5 4 3 Datalogger Setup 2 1 The following changes are possible Selection of the single value measurement mode by way of a switch This ensures that only one value will be re corded...

Страница 9: ...u item enables the measurement values of the measuring channels to be manually reset to zero To do so the switches of the desired channels are set from off to on by way of the arrow keys Fig 20 You ca...

Страница 10: ...played in the header The automatic rotation of the device display can be switched on and off Use the confirmation key in order to confirm a new setting 5 4 10 Setup Information 5 4 Here you can find g...

Страница 11: ...es minutes and seconds This menu item can only be used in combination with a Mo bile Link 2 GPS 12620 20 and GPS activated See also chapter 5 4 9 Coordinates will not be displayed unless satellites ha...

Страница 12: ...f the battery decreases strongly it is possible to change the battery Please note that damage resulting from a battery change are not covered by the warranty You can send the Mobile Link to the repair...

Страница 13: ...Unit Energy 12656 00 Cobra4 Sensor Unit Forceplate 12661 00 Cobra4 Sensor Unit Radioactivity 12665 00 Cobra4 Sensor Unit Sound Level 12669 00 Cobra4 Sensor Unit Weather air pressure humidity temperatu...

Отзывы: