background image

 

 

 

 

 

 

www.phywe.com, © All rights reserved 

 

12620-09 and 12620-10 / 2715

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If a sensor is connected, the name of the Cobra4 Sensor-Unit 
will be displayed in the header of the display (see Fig. 7).  

 

The navigation keys ▲▼ can be used to select the value that 
is to be displayed in a large form in the main field. 

The navigation key 

◄ opens the analogue display. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The navigation keys 

▲▼ can be used to select the value that 

is to be displayed in the analogue display. 

The  scaling  values  that  are  displayed  must  be  multiplied  by 
the value that is indicated in the lower left-hand corner. In the 
example above: value x1. 

The left arrow button 

◄ can be used to “zoom” the scaling of 

the  analogue  display.  In  doing  so,  the  values  of  the  display 
will be divided in half. Depending on the sensor, this can be 
performed up to three times. 

 

5.3

 

Measurement data recording process

 

A measurement can be started and stopped by pressing the 
confirmation key 

. The measurement data recording proc-

ess is indicated by a red, flashing dot in the upper right-hand 
corner  of  the  main  field  of  the  display.  The  recording  sym-
bol   in the lower display line turns into stop symbol  . The 
measurement values are saved to the memory card at the set 
measurement interval (Fig. 9). 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 7:  Display with a connected Cobra4 Sensor-Unit in the 

recording mode of the main display 

Fig. 6: Display when no sensor is connected to the unit. 

Fig. 8: Display without a connected Cobra4 Sensor-Unit 

Fig. 9:  Display without a connected Cobra4 Sensor-Unit in 

the recording mode of the main display 

Electricity

 

Voltage      U / V

 

0.00

 

I                     −0.01 A 

 

      

Header 

Main field 

Minor field 

Footer 

Acceleration

 

Acceleration      ax / g

 

0.00

 

ay                     −0.01 g 
az                     −1.00 g

 

 

      

Acceleration

 

      

ax                      

−0.01 g 

x1 

-2 

-1 

Acceleration

 

Acceleration      ax / g

 

0.00

 

ay                     −0.01 g 
az                     −1.00 g

 

 

      

Содержание 12620-09

Страница 1: ...nsor Setup 1 2 5 4 3 Datalogger Setup 2 1 5 4 4 Datalogger Files 2 2 5 4 5 Zero 3 5 4 6 Calibration 4 5 4 7 Setup Date Time 5 1 5 4 8 Setup Battery status 5 2 5 4 10 Setup Information 5 4 5 4 11 Setup...

Страница 2: ...supply unit 3 FUNCTIONAL AND OPERATING ELEMENTS 3 1 Operating elements on the top The Cobra4 Mobile Link 2 is equipped with various elements for the measurement data display operation and status indi...

Страница 3: ...nity of the unit After a complete shut down of the unit it must be switched off and on again by way of the ON OFF switch operating ele ment If the unit does not react keep the ON OFF switch pressed fo...

Страница 4: ...performed up to three times 5 3 Measurement data recording process A measurement can be started and stopped by pressing the confirmation key The measurement data recording proc ess is indicated by a...

Страница 5: ...The file name consists of the date and a running counter YYMMDDxx mli xx 00 99 Ensure that the date and time are set in the Cobra4 Mobile Link This can be checked and if needed changed in the Setup m...

Страница 6: ...Unit Conductivity 12632 00 It enables the automatic temperature compensation of a pH or conductivity measuring channel e g T 1 with regard to a temperature input or the manual input of a known temper...

Страница 7: ...e following Cobra4 Sen sor Units Cobra4 Sensor Unit Radioactivity 12665 00 It is used to change the counter tube voltage in order to measure the counter tube characteristics Gate time This setting opt...

Страница 8: ...imer Counter 12651 00 5 4 3 Datalogger Setup 2 1 The following changes are possible Selection of the single value measurement mode by way of a switch This ensures that only one value will be re corded...

Страница 9: ...u item enables the measurement values of the measuring channels to be manually reset to zero To do so the switches of the desired channels are set from off to on by way of the arrow keys Fig 20 You ca...

Страница 10: ...played in the header The automatic rotation of the device display can be switched on and off Use the confirmation key in order to confirm a new setting 5 4 10 Setup Information 5 4 Here you can find g...

Страница 11: ...es minutes and seconds This menu item can only be used in combination with a Mo bile Link 2 GPS 12620 20 and GPS activated See also chapter 5 4 9 Coordinates will not be displayed unless satellites ha...

Страница 12: ...f the battery decreases strongly it is possible to change the battery Please note that damage resulting from a battery change are not covered by the warranty You can send the Mobile Link to the repair...

Страница 13: ...Unit Energy 12656 00 Cobra4 Sensor Unit Forceplate 12661 00 Cobra4 Sensor Unit Radioactivity 12665 00 Cobra4 Sensor Unit Sound Level 12669 00 Cobra4 Sensor Unit Weather air pressure humidity temperatu...

Отзывы: