6 Configuration
6.1 Insulation Overview
Fig. 4: Insulation MSD2
+
The brake must be operated with protective measure PELV. The transformer should be
constructed with reinforced or double insulation.
The internally installed switching power supply has double insulation.
The device has been designed for degree of pollution 2 acc. to EN 50178.
The IO signals on connector X3 are optically insulated and safely insulated to withstand
voltages up to 800 V
DC
.