3 The MSD2
+
Power Stage
The power stages type MSD2
+
are used for bipolar control of two-phase stepper motors
with Phytron´s well-tried technology, now with enhanced 4 quadrant chopper type current
control.
MSD2
+
includes a supply unit and therefore can directly be connected to the mains voltage
(115 or 230 V
AC
).
In addition, the MSD2+ enables the control of an attached (permanent magnet) motor
brake.
The MSD2+ is available in two operating modes:
Option "KS" (rotary switch mode): the operating parameters - e.g. run current, step
resolution, motor direction of rotation - are set via the rotary switches.
Options "SB" (ServiceBus mode): The + of the power stage MSD2+ stands for "operation
with ServiceBus". The ServiceBus enables the configuration, programming and
diagnostics of the power stage with the free downloadable software ServiceBus-Comm
TM
for Windows
®
via the PC.
Motor current
1.1 up to 15.4 A
peak
Mains voltage from
115 up to 230 V
AC
120 V
DC
supply voltage
Step resolution from full step to
1/20 step
Option “SB”: Configuration of the
power stage via ServiceBus
Option „KS“: Setting of operating
parameters via rotary switches
Short-circuit proof over and between
the phases and towards ground
Rack- or wall mounting
Brake control
Fig. 1: Front view of the MSD2
+
with the front panel