Part I: PCM-049/phyCORE-OMAP44xx System on Module
phyCORE-OMAP44xx
26
©
PHYTEC Messtechnik GmbH
2012
L-760e_1
Pin Row X1D
Pin #
Signal
I/O
SL
Description
1D
VCC_3V3_IN
I
Power
3.3 V Primary voltage supply input
2D
VCC_3V3_IN
I
Power
3.3 V Primary voltage supply input
3D
VCC_3V3_IN
I
Power
3.3 V Primary voltage supply input
4D
VCC_3V3_IN
I
Power
3.3 V Primary voltage supply input
5D
VCC_3V3_IN
I
Power
3.3 V Primary voltage supply input
6D
GND
-
-
Ground 0V
7D
X_nRESET_PWRON
I/O
1.8 V
System reset: output of PMIC,
input of controller
8D
X_nRESET_PER
I/O
1.8 V
Peripheral reset: output of
controller, input of Ethernet
controller and USB PHY
9D
GND
-
-
Ground 0V
10D
X_UART1_RX
I
1.8 V
Serial receive signal UART 1
11D
X_UART3_RS232_TX
O
RS-232
Serial transmit signal UART 3
12D
X_UART3_RS232_RX
I
RS-232
Serial receive signal UART 3
13D
X_UART2_TX
O
VCC_1V8_IO
Serial transmit signal UART 2
14D
GND
-
-
Ground 0V
15D
X_UART2_RX
I
1.8 V
Serial receive signal UART 2
16D
X_UART4_TX
O
VCC_1V8_IO
Serial transmit signal UART 4
17D
X_UART4_RX
I
1.8 V
Serial receive signal UART 4
18D
X_USBB1_OC_GPIO_120
I
1.8 V
USB Host overcurrent signal input
19D
GND
-
-
Ground 0V
20D
X_USBB1_DP
I/O
USB
USB Host data plus
21D
X_USBB1_DM
I/O
USB
USB Host data minus
22D
X_USBB1_PWR
O
VCC_3V3_S
External USB bus voltage (5V)
enable
23D
3V3_S Reference Voltage
O
VCC_3V3_S
3.3 V (VCC_3V3_S) reference
voltage
24D
GND
-
-
Ground 0V
25D
X
I
VCC_3V3_S
Ethernet receive positive input
26D
X_ETH_RX-
I
VCC_3V3_S
Ethernet receive negative input
27D
X_ETH_LINK
O
VCC_3V3_S
Ethernet link indicator
(open drain)
28D
X_GPIO_WK30
I/O
1.8 V / VCC_1V8_IO GPIO WK30
Table 5:
Pin-out of the phyCORE-Connector X1, Row D
Содержание phyCORE-OMAP44 Series
Страница 10: ...phyCORE OMAP44xx PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 20: ...phyCORE OMAP44xx 8 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 22: ...Part I PCM 049 phyCORE OMAP44xx System on Module phyCORE OMAP44xx 10 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 46: ...Part I PCM 049 phyCORE OMAP44xx System on Module phyCORE OMAP44xx 34 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 70: ...Part I PCM 049 phyCORE OMAP44xx System on Module phyCORE OMAP44xx 58 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 84: ...Part I PCM 049 phyCORE OMAP44xx System on Module phyCORE OMAP44xx 72 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 92: ...Part II PCM 959 phyCORE OMAP44xx Carrier Board phyCORE OMAP44xx 80 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 166: ...Part II PCM 959 phyCORE OMAP44xx Carrier Board phyCORE OMAP44xx 154 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 168: ...Revision History phyCORE OMAP44xx 172 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...