phyCORE-OMAP44xx
Part I: PCM-049/phyCORE-OMAP44xx System on Module
L-760e_1 © PHYTEC Messtechnik GmbH 2012
25
40C
X_HDMI_CLOCKY
O
HDMI
HDMI display clock differential
positive or negative
1
41C
GND
-
-
Ground 0V
42C
X_PMIC_SYSEN
O
1.8 V
PMIC external system enable
43C
X_PMIC_PREQ3
I
1.8 V
PMIC peripheral 3 power request
input
44C
X_PMIC_PREQ2A
I/O
1.8 V / VCC_1V8_IO PMIC peripheral 2A power request
input / Ethernet controller power
management event signal (PME)
45C
GND
-
-
Ground 0V
46C
X_DSI1_DX0
O
DSI
DSI1 display lane 0 differential
positive or negative
1
47C
X_DSI1_DY0
O
DSI
DSI1 display lane 0 differential
positive or negative
1
48C
X_DSI1_DX2
O
DSI
DSI1 display lane 2 differential
positive or negative
1
49C
X_DSI_DY2
O
DSI
DSI1 display lane 2 differential
positive or negative
1
50C
GND
-
-
Ground 0V
51C
X_DSI1_DX4
O
DSI
DSI1 display lane 4 differential
positive or negative
1
52C
X_DSI1_DY4
O
DSI
DSI1 display lane 4 differential
positive or negative
1
53C
X_I2C1_SCL
O
VCC_1V8_IO
I
2
C1 clock (open drain)
54C
X_I2C1_SDA
I/O
1.8 V / VCC_1V8_IO I
2
C1 data (open drain)
55C
GND
-
-
Ground 0V
56C
X_1-WIRE_3V3
I/O
3.3 V
Hardware Introspection Interface
For internal use only
57C
X_BOOT0
I
1.8 V
System boot configuration pin 0
58C
X_BOOT2
I
1.8 V
System boot configuration pin 2
59C
X_BOOT4
I
1.8 V
System boot configuration pin 4
60C
GND
-
-
Ground 0V
1.
Can be configured by setting the appropriate control register. Please refer to the OMAP44xx Reference manual for more information.
Pin Row X1C
Pin #
Signal
I/O
SL
Description
Table 4:
Pin-out of the phyCORE-Connector X1, Row C
Содержание phyCORE-OMAP44 Series
Страница 10: ...phyCORE OMAP44xx PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 20: ...phyCORE OMAP44xx 8 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 22: ...Part I PCM 049 phyCORE OMAP44xx System on Module phyCORE OMAP44xx 10 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 46: ...Part I PCM 049 phyCORE OMAP44xx System on Module phyCORE OMAP44xx 34 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 70: ...Part I PCM 049 phyCORE OMAP44xx System on Module phyCORE OMAP44xx 58 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 84: ...Part I PCM 049 phyCORE OMAP44xx System on Module phyCORE OMAP44xx 72 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 92: ...Part II PCM 959 phyCORE OMAP44xx Carrier Board phyCORE OMAP44xx 80 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 166: ...Part II PCM 959 phyCORE OMAP44xx Carrier Board phyCORE OMAP44xx 154 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 168: ...Revision History phyCORE OMAP44xx 172 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...