phyCORE-OMAP44xx
Part II: PCM-959/phyCORE-OMAP44xx Carrier Board
L-760e_1 © PHYTEC Messtechnik GmbH 2012
151
2.1.3.21.12 Power Signal Mapping
The expansion connector X5 provides the power signals of the carrier board and the phyCORE-OMAP44xx.
2.1.3.21.13 Signals freely available as GPIO
Signal
Pin #
I/O
SL
Description
GND
X5C42, X5C43,
X5C44, X5C45,
X5D42, X5D43,
X5D44, X5D45
-
-
Ground
V_BAT
X5C46
O
3.3 V
Backup voltage
VCC_3V3_S
X5C47, X5C48
O
3.3 V
3.3 V reference voltage
VCC_1V8
X5C49 - X5C51,
X5D49 - X5D51
O
1.8 V
1.8 V voltage domain
VCC_3V3
X5C52 - X5C54,
X5D52 - X5D54
O
3.3 V
3.3 V reference domain
VCC_5V
X5C55 - X5C57,
X5D55 - X5D57
O
5 V
5V voltage domain
VCC_12_24
X5C58 - X5C60,
X5D58 - X5D60
O
12 V - 24 V
+12 V to +24 V voltage domain
VCC_1V8_IO
X5D47, X5D48
O
1.8 V
1.8 V reference domain
VCC_1V2
X5D33
O
1.2 V
1.2 V reference domain
Table 81:
Power Signal Mapping
Signal
Pin #
I/O
SL
Description
X_CSI21_DX0
X5C18
I
CSI
GPI 67, or CSI2-A (CSI21) differential
clock positive input
X_CSI21_DY0
X5C19
I
CSI
GPI 68, or CSI2-A (CSI21) differential
clock negative input
X_CSI21_DX1
X5C20
I
CSI
GPI 69, or CSI2-A (CSI21) differential
data lane positive input 1
X_CSI21_DY1
X5C21
I
CSI
GPI 70, or CSI2-A (CSI21) differential
data lane negative input 1
X_CSI21_DX2
X5C22
I
CSI
GPI 71, or CSI2-A (CSI21) differential
data lane positive input 2
X_CSI21_DY2
X5C23
I
1.8 V/CSI
GPI 72, or CSI2-A (CSI21) differential
data lane negative input 2
X_UART1_TX
X5C35
I/O
1.8 V
GPIO 129, or UART1 transmit
X_UART1_RX
X5C36
I/O
1.8 V
GPIO 128, or UART1 receive
X_SDMMC1_DAT4
X5D1
I/O
VCC_MMC1
GPIO 106, or SD/MMC1 Data 4
X_SDMMC1_DAT5
X5D2
I/O
VCC_MMC1
GPIO 107, or SD/MMC1 Data 5
Table 82:
Signals freely available as GPIO
Содержание phyCORE-OMAP44 Series
Страница 10: ...phyCORE OMAP44xx PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 20: ...phyCORE OMAP44xx 8 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 22: ...Part I PCM 049 phyCORE OMAP44xx System on Module phyCORE OMAP44xx 10 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 46: ...Part I PCM 049 phyCORE OMAP44xx System on Module phyCORE OMAP44xx 34 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 70: ...Part I PCM 049 phyCORE OMAP44xx System on Module phyCORE OMAP44xx 58 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 84: ...Part I PCM 049 phyCORE OMAP44xx System on Module phyCORE OMAP44xx 72 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 92: ...Part II PCM 959 phyCORE OMAP44xx Carrier Board phyCORE OMAP44xx 80 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 166: ...Part II PCM 959 phyCORE OMAP44xx Carrier Board phyCORE OMAP44xx 154 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...
Страница 168: ...Revision History phyCORE OMAP44xx 172 PHYTEC Messtechnik GmbH 2012 L 760e_1 ...