Getting Started
© PHYTEC Meßtechnik GmbH 2002 L-462e_2
27
If the selected Flash bank into which you wish to download code is
not empty (i.e. erased), a warning dialog box will appear,
indicating “Location not empty! Please erase location and try
again”. In this event, select the Bank Utilities tab from the
FlashTools98 tabsheet, highlight Bank #1 and erase the bank. Then
repeat the download procedure.
•
At the end of the download, a sector-by-sector status check of the
Flash memory can be viewed in the lower left corner of the
FlashTools98 tabsheet window. Wait until the status check
finishes before returning to work with the board. Once the status
check is complete, the downloaded code can be executed.
•
Returning to the Communication tab, click on the Disconnect
button and exit FlashTools98.
•
Press the Reset button (S2) on the phyCORE Development
Board LD 5V to reset the target hardware and to start execution of
the downloaded software.
•
Successful execution of the program will flash the LED D3 with
equal on and off durations.
Содержание phyCORE-ADuC812