![Phytec phyCORE-167CR Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/phytec/phycore-167cr/phycore-167cr_hardware-manual_1554145090.webp)
phyCORE-167CR/167CS
80
PHYTEC Meßtechnik GmbH 2002 L-527e_8
3.
The CAN transceiver populating the phyCORE-167CS is disabled;
CAN signals generated by the CAN transceiver (U3) on the
Development Board extend to connector P2B with galvanic
separation. This configuration requires connection of an external
CAN supply voltage of 7 to 13 V. The external power supply must
be only connected to either P2A or P2B.
Jumper
Setting
Description
JP33
2 + 3
Pin 2 of DB-9 plug P2B connected with CAN-L1 from
CAN transceiver U3 on the Development Board
JP34
1 + 2
Pin 7 of DB-9 plug P2B connected with CAN-H1 from
CAN transceiver U3 on the Development Board
2 + 3
Input at opto-coupler U6 on the Development Board
connected to CAN2_Tx (P4.6
JP14
1 + 2
Input at opto-coupler U4 on the Development Board
connected to CAN2_Tx (P8.3
2 + 3
Output at opto-coupler U7 on the Development Board
connected to CAN2_Rx (P4.4
JP15
1 + 2
Output at opto-coupler U7 on the Development Board
connected to CAN2_Rx (P8.2
JP13
1 + 2
Supply voltage for CAN transceiver and opto-coupler
on the Development Board derived from external source
(CAN bus) via on-board voltage regulator
JP18
open
CAN transceiver and opto-coupler on the Development
Board disconnected from local GND potential
JP29
closed
Supply voltage for on-board voltage regulator
from pin 9 of DB-9 plug P2A
Table 44:
Jumper Configuration for CAN Plug P2A using the CAN Transceiver
on the Development Board with Galvanic Separation (only with
C167CS)
1:
Port P4.7 is the default port for CAN2_Tx (standard).
2:
Port P8.3 is the alternative port for CAN2_Tx (see C167CS User‘s Manual/Data Sheet).
3:
Port P4.4 is the default port for CAN2_Rx (standard).
4:
Port P8.2 is the alternative port for CAN2_Rx (see C167CS User‘s Manual/Data Sheet).
Содержание phyCORE-167CR
Страница 10: ...phyCORE 167CR 167CS PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 24: ...phyCORE 167CR 167CS 14 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 40: ...phyCORE 167CR 167CS 30 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 50: ...phyCORE 167CR 167CS 40 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 102: ...phyCORE 167CR 167CS 92 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 112: ...phyCORE 167CR 167CS 102 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 114: ...Published by PHYTEC Me technik GmbH 2002 Ordering No L 527e_8 Printed in Germany...