![Phytec phyCORE-167CR Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/phytec/phycore-167cr/phycore-167cr_hardware-manual_1554145082.webp)
phyCORE-167CR/167CS
72
PHYTEC Meßtechnik GmbH 2002 L-527e_8
14.3.5
First CAN Interface at Plug P2A
Plug P2A is the lower plug of the double DB-9 connector at P2. P2A
is connected to the first CAN interface (CAN0) of the
phyCORE-167CR/167CS via jumpers. Depending on the configu-
ration of the CAN transceivers and their power supply, the following
three configurations are possible:
1.
CAN transceiver populating the phyCORE-167CR/167CS is
enabled and the CAN signals from the module extend directly to
plug P2A.
Jumper
Setting
Description
JP31
2 + 3
Pin 2 of the DB-9 plug P2A is connected to CAN-L0
from on-board transceiver on the phyCORE module
JP32
2 + 3
Pin 7 of the DB-9 plug P2A is connected to CAN-H0
from on-board transceiver on the phyCORE module
JP11
open
Input at opto-coupler U4 on the phyCORE
Development Board HD200 open
JP12
open
Output at opto-coupler U5 on the phyCORE
Development Board HD200 open
JP13
open
No supply voltage to CAN transceiver and opto-coupler
on the phyCORE Development Board HD200
JP18
open
No GND potential at CAN transceiver and opto-coupler
on the phyCORE Development Board HD200
JP29
open
No power supply via CAN bus
Table 36:
Jumper Configuration for CAN Plug P2A using the CAN Transceiver
on the phyCORE-167CR/167CS
Pin 3:
GND (Development Board Ground)
Pin 7:
CAN-H0 (not galvanically separated)
Pin 2:
CAN-L0 (not galvanically separated)
Pin 6:
GND (Development Board Ground)
Figure 17:
Pin Assignment of the DB-9 Plug P2A (CAN Transceiver on
phyCORE-167CR/167CS, Front View)
1
2
3
4
7
6
5
8
9
Содержание phyCORE-167CR
Страница 10: ...phyCORE 167CR 167CS PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 24: ...phyCORE 167CR 167CS 14 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 40: ...phyCORE 167CR 167CS 30 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 50: ...phyCORE 167CR 167CS 40 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 102: ...phyCORE 167CR 167CS 92 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 112: ...phyCORE 167CR 167CS 102 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 114: ...Published by PHYTEC Me technik GmbH 2002 Ordering No L 527e_8 Printed in Germany...