Caution:
When using the DB-9 connector P2A as CAN interface and the CAN
transceiver on the Development Board the following jumper settings
are not functional and could damage the module:
Jumper
Setting
Description
JP31
2 + 3
Pin 2 of DB-9 plug P2A connected with CAN-L0 from
on-board transceiver on the phyCORE-167CR/167CS
JP32
2 + 3
Pin 7 of DB-9 plug P2A connected with CAN-H0 from
on-board transceiver on the phyCORE-167CR/167CS
JP11
open
Input at opto-coupler U4 on the Development Board
not connected
JP12
open
Output at opto-coupler U5 on the Development Board
not connected
JP13
1 + 2
Supply voltage for CAN transceiver and opto-coupler
on the Development Board derived from external
source (CAN bus) via on-board voltage regulator
JP29
closed
Supply voltage for on-board voltage regulator
from pin 9 of DB-9 connector P2A
Table 38:
Improper Jumper Settings for the CAN Plug P2A (CAN Transceiver
on the Development Board)
Содержание phyCORE-167CR
Страница 10: ...phyCORE 167CR 167CS PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 24: ...phyCORE 167CR 167CS 14 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 40: ...phyCORE 167CR 167CS 30 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 50: ...phyCORE 167CR 167CS 40 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 102: ...phyCORE 167CR 167CS 92 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 112: ...phyCORE 167CR 167CS 102 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 114: ...Published by PHYTEC Me technik GmbH 2002 Ordering No L 527e_8 Printed in Germany...