![Phytec phyCORE-167CR Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/phytec/phycore-167cr/phycore-167cr_hardware-manual_1554145037.webp)
Jumpers
PHYTEC Meßtechnik GmbH 2002 L-527e_8
27
The following CAN interface configurations are possible:
Interface CAN1
J16
J17
P4.5 (CAN1Rx)
P4.6 (CAN1Tx)
2 + 3*
2 + 3*
P8.0 (CAN1Rx)
P8.1 (CAN1Tx)
1 + 2
1 + 2
Interface CAN2
J18
J19
P4.4 (CAN2Rx)
P4.7 (CAN2Tx)
2 + 3*
2 + 3*
P8.2 (CAN2Rx)
P8.3 (CAN2Tx)
1
1 + 2
1 + 2
* = Default setting
Table 14:
J16, J17, J18, J19 CAN Interface Configuration
3.13
J20 Remote Download Source
Space U8 on the module is intended to be populated by a Remote
Supervisory Chip
. This IC can initiate a boot sequence via various
serial interfaces (refer to section 6). Jumper J20 is reserved for future
use and remains open as default.
The following configurations are possible:
Download Source
J20
not available
open*
Port P3.11 / RxD0
2 + 6
Port P3.1 / RxD1
1 + 2
Port CAN1Rx
3 + 5
Port CAN2Rx
3 + 4
* = Default setting
Table 15:
J20 Remote Download Source Configuration
1
:
Rerouting CAN signals to port P8 is only available with Infineon’s C167CS controller.
Caution: Ensure correct configuration of the bit field IPC (in controller register PCIR) to
allow proper use of the CAN interface (refer to the microcontroller User‘s Manual and Data
Sheet for further information).
2
:
The second CAN interface is only available with Infineon’s C167CS controller.
3
:
This feature is under development and not available at this time.
Содержание phyCORE-167CR
Страница 10: ...phyCORE 167CR 167CS PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 24: ...phyCORE 167CR 167CS 14 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 40: ...phyCORE 167CR 167CS 30 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 50: ...phyCORE 167CR 167CS 40 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 102: ...phyCORE 167CR 167CS 92 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 112: ...phyCORE 167CR 167CS 102 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 114: ...Published by PHYTEC Me technik GmbH 2002 Ordering No L 527e_8 Printed in Germany...