![Phytec phyCORE-167CR Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/phytec/phycore-167cr/phycore-167cr_hardware-manual_1554145076.webp)
phyCORE-167CR/167CS
66
PHYTEC Meßtechnik GmbH 2002 L-527e_8
Caution:
When using the DB-9 socket P1A as RS-232 interface on the
phyCORE-167CR/167CS the following jumper settings are not
functional and could damage the module:
Jumper
Setting
Description
JP20
open
Pin 2 of DB-9 socket P1A not connected, no
connection to TxD0 signal from phyCORE-
167CR/167CS
JP21
closed
Pin 9 of DB-9 socket P1A connected with port P8.2
from phyCORE-167CR/167CS
JP22
1 + 2
Pin 7 of DB-9 socket P1A connected with port P2.15
from phyCORE-167CR/167CS
JP23
1 + 2
Pin 4 of DB-9 socket P1A connected with port P8.0
from phyCORE-167CR/167CS
JP24
closed
Pin 6 of DB-9 socket P1A connected with port P8.1
from phyCORE-167CR/167CS
JP25
closed
Pin 8 of DB-9 socket P1A connected with port P2.14
from phyCORE-167CR/167CS
JP26
closed
Pin 1 of DB-9 socket P1A connected with port P8.3
from phyCORE-167CR/167CS
JP27
open
Pin 3 of DB-9 socket P1A not connected, no
connection to RxD0 signal from phyCORE-
167CR/167CS
Table 30:
Improper Jumper Settings for DB-9 Socket P1A as First RS-232
If an RS-232 cable is connected to P1A, the voltage level on the
RS-232 lines could destroy the phyCORE-167CR/167CS.
Содержание phyCORE-167CR
Страница 10: ...phyCORE 167CR 167CS PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 24: ...phyCORE 167CR 167CS 14 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 40: ...phyCORE 167CR 167CS 30 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 50: ...phyCORE 167CR 167CS 40 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 102: ...phyCORE 167CR 167CS 92 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 112: ...phyCORE 167CR 167CS 102 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 114: ...Published by PHYTEC Me technik GmbH 2002 Ordering No L 527e_8 Printed in Germany...