![Phytec phyCORE-167CR Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/phytec/phycore-167cr/phycore-167cr_hardware-manual_1554145081.webp)
The phyCORE-167CR/167CS on the phyCORE-Development Board
PHYTEC Meßtechnik GmbH 2002 L-527e_8
71
Caution:
If the phyCORE-167CR/167CS is NOT populated with the optional
UART at U7 (standard PCM-009-Cx) and the DB-9 socket P1B is
used as described above the following jumper settings are not
functional and could damage the module:
Jumper
Setting
Description
JP2
closed
No RI1_TTL signal available from the
phyCORE-167CR/167CS (P1B pin 9)
JP3
closed
No CTS1_RS232 signal available from the
phyCORE-167CR/167CS (P1B pin 7)
JP4
closed
No DSR1_RS232 signal available from the
phyCORE-167CR/167CS (P1B pin 4)
JP5
closed
No DTR1_RS232 signal available from the
phyCORE-167CR/167CS (P1B pin 6)
JP6
closed
No RTS1_RS232 signal available from the
phyCORE-167CR/167CS (P1B pin 8)
JP7
closed
No CD1_RS232 signal available from the
phyCORE-167CR/167CS (P1B pin 1)
Table 35:
Improper Jumper Settings for DB-9 Socket P1B (2
nd
RS-232 via
Software Emulation)
Содержание phyCORE-167CR
Страница 10: ...phyCORE 167CR 167CS PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 24: ...phyCORE 167CR 167CS 14 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 40: ...phyCORE 167CR 167CS 30 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 50: ...phyCORE 167CR 167CS 40 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 102: ...phyCORE 167CR 167CS 92 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 112: ...phyCORE 167CR 167CS 102 PHYTEC Me technik GmbH 2002 L 527e_8...
Страница 114: ...Published by PHYTEC Me technik GmbH 2002 Ordering No L 527e_8 Printed in Germany...