eGrabber-4plus
180
PHYTEC Meßtechnik GmbH 2004 L-608e_4
•
Hardware Compatibility
All of the signals available on the eGrabber-2 are also available at
the same sockets and contacts on the eGrabber-4plus. Connector
cables previously used for the eGrabber-2 can also be used for the
eGrabber-4plus.
With the eGrabber-4plus some signals have been added to pin
header row X3. The pin header row therefore has 6 additional
pins when compared to that of the eGrabber-2. If you should
choose to implement the eGrabber-4plus in an existing application
as a substitution for an eGrabber-2, you can simply remove the last
6 pins from the pin header row X3. The first 20 pins are identical
to those of the eGrabber-2 and you can power it with the same
power adapter.
In order to make it easier for you to remove the pins, those pis that
are compatible with the eGrabber-2 have a white border around
them.
One of the main differences between the eGrabber-4plus and the
eGrabber-2 is that the SMB-Sockets P3 and P4 have been
removed. Previously it was possible to feed in an S-Video signal
via these sockets. This function is now taken over by the Mini-
DIN-Socket X4
Two pins have been altered on the expansion connector
(Option Port, X6) (see Table 14).
Option Port, X6
Pin Function
Pin
Function
Pin
Function
1
+5V out
8
I/O 6
15
I/O-Pin
2
I/O0
9
I/O 7
16
I/O Clk
3
I/O1
10
I/O 8
17
I²C SCL
4
I/O2
11
I/O 9
18
I²C SDA
5
I/O3
12
I/O 10
19
GND
6
I/O4
13
I/O 11
20
GND
7
I/O5
14
N.C.
bold = new function
Table 14:
Pin Assignment of the Option Port - Connectors (Both Models)
Содержание eGrabber-4plus
Страница 1: ...A product of a PHYTEC Technology Holding company eGrabber 4plus Hardware Manual Edition June 2004 ...
Страница 8: ...eGrabber 4plus PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 10: ...eGrabber 4plus PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 56: ...eGrabber 4plus 46 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 80: ...eGrabber 4plus 70 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 81: ...Part 2 Programmer s Manual PHYTEC Meßtechnik GmbH 2004 L 608e_4 71 Part 2 Programmer s Manual ...
Страница 82: ...eGrabber 4plus 72 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 137: ...Driver Software PHYTEC Meßtechnik GmbH 2004 L 608e_4 127 Figure 52 Color Format of the eGrabber 4plus ...
Страница 188: ...eGrabber 4plus 178 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 192: ...eGrabber 4plus 182 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 204: ...eGrabber 4plus 194 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 206: ...Published by PHYTEC Meßtechnik GmbH 2004 Ordering No L 608e_4 Printed in Germany ...