eGrabber-4plus
110
PHYTEC Meßtechnik GmbH 2004 L-608e_4
Ø
Configuring the Input Channels
void Set_ChannelEx(WORD nDevNo, WORD nChannel);
nChannel: Input channel to be configured (1…9 / 1…3)
This function is used to select the input channel. The signal is directed
by a dual-row multiplexer. The first row is externally located on the
Grabber board, and the second row is integrated into the video
multiplexer.
Values:
EPC-032 :
Channel numbers 1 through 3 are allowed
EPC-032-X1:
Channel numbers 1 through 9 are allowed
EPC-032-X2 :
Channel numbers 1 through 3 are allowed
EPC-032-X1-X2: Channel numbers 1 through 9 are allowed
This function is not compatible with the eGrabber-2 (EPC-032) and
eGrabber-2 (EPC-031).
Note:
Configuring the input channels is not necessary when using S-Video
sources! The function Set_S_VideoEx() switches the channels
automatically.
Caution:
When switching input channels, stop inhibit times are to be taken care
of until an image for the new channel has been digitized,.
For the following reasons,
•
Definition of the video signal normally lasts up to 4 half images
before synchronization is implemented and the color system
functions correctly.
•
Due to DC voltage decoupling between the Grabber and the
camera, different average DC levels on signal lines are present.
This can cause charge transfer effects while switching over.
•
The Grabber card’s AGC must first be configured to the new signal
level.
Содержание eGrabber-4plus
Страница 1: ...A product of a PHYTEC Technology Holding company eGrabber 4plus Hardware Manual Edition June 2004 ...
Страница 8: ...eGrabber 4plus PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 10: ...eGrabber 4plus PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 56: ...eGrabber 4plus 46 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 80: ...eGrabber 4plus 70 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 81: ...Part 2 Programmer s Manual PHYTEC Meßtechnik GmbH 2004 L 608e_4 71 Part 2 Programmer s Manual ...
Страница 82: ...eGrabber 4plus 72 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 137: ...Driver Software PHYTEC Meßtechnik GmbH 2004 L 608e_4 127 Figure 52 Color Format of the eGrabber 4plus ...
Страница 188: ...eGrabber 4plus 178 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 192: ...eGrabber 4plus 182 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 204: ...eGrabber 4plus 194 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 206: ...Published by PHYTEC Meßtechnik GmbH 2004 Ordering No L 608e_4 Printed in Germany ...