Driver Software
PHYTEC Meßtechnik GmbH 2004 L-608e_4
139
Ø
ê
Number of Processed Digitized Images
With the eGrabber-4plus, it is possible to count the number of
digitized images. The following two functions are used for this
purpose:
These functions are not compatible with the eGrabber-2.
BYTE Get_CaptureCounter (WORD nDevNo)
return value:
Number of grabbed fields module 256
The function returns the number of digitized half frames. The result is
a Byte value and the counter jumps from 255 to 0.
void Reset_CaptureCounter (WORD nDevNo)
Calling this routine sets the half frame counter back to zero.
Ø
Setting the brightness of the image
void Set_Brightness(WORD nDevNo, short nBright);
nBright:
brightness of the image (-128..127)
This function specifies the value in the register for the brightness in
the video processor. The value is a constant added to the brightness of
a single pixel. This brightness can be varied from –50 % to +49.6 %.
One LSB corresponds to a change in brightness of 0.39 %:
nBright =
brightness[%]
.
2.5601 [1/%]
Содержание eGrabber-4plus
Страница 1: ...A product of a PHYTEC Technology Holding company eGrabber 4plus Hardware Manual Edition June 2004 ...
Страница 8: ...eGrabber 4plus PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 10: ...eGrabber 4plus PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 56: ...eGrabber 4plus 46 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 80: ...eGrabber 4plus 70 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 81: ...Part 2 Programmer s Manual PHYTEC Meßtechnik GmbH 2004 L 608e_4 71 Part 2 Programmer s Manual ...
Страница 82: ...eGrabber 4plus 72 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 137: ...Driver Software PHYTEC Meßtechnik GmbH 2004 L 608e_4 127 Figure 52 Color Format of the eGrabber 4plus ...
Страница 188: ...eGrabber 4plus 178 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 192: ...eGrabber 4plus 182 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 204: ...eGrabber 4plus 194 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 206: ...Published by PHYTEC Meßtechnik GmbH 2004 Ordering No L 608e_4 Printed in Germany ...