eGrabber-4plus
138
PHYTEC Meßtechnik GmbH 2004 L-608e_4
Ø
ê
Checking for a video signal
WORD Get_Signal_Status(WORD nDevNo);
return value: 0 = no video signal at input
1 = undefined
2 = video signal present
3 = video signal present and line locked
With the help of this function it is recognized, if a camera is connected
to the selected channel. In addition the quality of the signal can be
evaluated.
The returnvalue 0 indicates, that no source is connected to the selected
channel. If no synchronizing pulses are detected for 31 lines, it is
anticipated, that no source is applied.
If the returnvalue is 2, a source is applied. Interference at the input can
cause a wrong indication.
The returnvalue 3 indicates a stable videosignal, which stems with
high probability from an image source. This value is generated in case
the horizontal synchronizing pulse is found within
±
1 clock of the
expected position. This must be given for 32 lines in sequence. Vice
versa the „HLOCK“ status will be not indicated, in case this criteria is
not fulfilled for 32 consecute lines. Therefor this indication will be
very reliable. Some image sources such as a videorecorder tend to not
having a stable timing. For such devices it might be possible, that the
returnvalue 3 will never be indicated. Nevertheless digitization will be
faultless by using the U
LTRALOCK
-synchronization.
Содержание eGrabber-4plus
Страница 1: ...A product of a PHYTEC Technology Holding company eGrabber 4plus Hardware Manual Edition June 2004 ...
Страница 8: ...eGrabber 4plus PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 10: ...eGrabber 4plus PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 56: ...eGrabber 4plus 46 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 80: ...eGrabber 4plus 70 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 81: ...Part 2 Programmer s Manual PHYTEC Meßtechnik GmbH 2004 L 608e_4 71 Part 2 Programmer s Manual ...
Страница 82: ...eGrabber 4plus 72 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 137: ...Driver Software PHYTEC Meßtechnik GmbH 2004 L 608e_4 127 Figure 52 Color Format of the eGrabber 4plus ...
Страница 188: ...eGrabber 4plus 178 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 192: ...eGrabber 4plus 182 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 204: ...eGrabber 4plus 194 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Страница 206: ...Published by PHYTEC Meßtechnik GmbH 2004 Ordering No L 608e_4 Printed in Germany ...